S82Y-VM60D Omron, S82Y-VM60D Datasheet - Page 17

DIN Rail Mtg Bkt K For 600 W

S82Y-VM60D

Manufacturer Part Number
S82Y-VM60D
Description
DIN Rail Mtg Bkt K For 600 W
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S82Y-VM60D

Accessory Type
Mounting Bracket(s)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S8VM Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82YVM60D
Z2814
S8VM-600@@C
100 VAC, Load ratio: 100%
200 VAC, Load ratio: 100%
S8VM-15224C
100 VAC, Load ratio: 100%
200 VAC, Load ratio: 100%
(10 A/DIV)
(10 A/DIV)
(25 A/DIV)
(10 A/DIV)
AC input
AC input
AC input
AC input
AC input
AC input
AC input
AC input
voltage
voltage
voltage
voltage
current
voltage
voltage
current
Output
current
voltage
voltage
Output
Output
current
Output
100 ms
100 ms
100 ms
100 ms
■ Reference Values
■ Overload Protection
The Power Supply is automatically protected from short-circuit or
overcurrent damage by the overload protection function. Overload
protection is activated if the output current rises above 105% of the
rated current.
S8VM-300@@C/600@@C
When the output current returns within the rated range, overload pro-
tection is automatically cleared.
S8VM-15224C
Outputs are interrupted if an overload continues for 5 seconds or
more. To reset the Power Supply, leave input power OFF for more
than 3 minutes and then turn it ON again. Alternatively, turn OFF and
ON the remote control signal.
The values shown in the above diagrams are for reference only.
Note: 1. If the Power Supply has been short-circuited or supplied
Reliability
(MTBF)
Life
expectancy
300W/600W (5 V)
0
Item
Intermittent operation
2. The internal parts may possibly be deteriorated or dam-
Switch Mode Power Supply
with an overcurrent longer than 30 seconds, the internal
parts of the Power Supply may occasionally be deteriorated
or damaged.
aged. Do not use the Power Supply for applications where
the load causes frequent inrush current and overload.
50
300 W:
135,000 hrs
600 W:
120,000 hrs
1,500 W:
100,000 hrs
10 yrs. min.
Output current (%)
Value
100
MTBF stands for Mean Time Between Failures, which
is calculated according to the probability of accidental
device failures, and indicates the reliability of a device.
Therefore, it does not necessarily represent the life of
the Power Supply.
The life expectancy indicates average operating hours
under the ambient temperature of 40 ° C and a load rate
of 50%.
Normally this is determined by the life expectancy of
the built-in aluminum electrolytic capacitor.
300W600W/1,500W (12 V, 15 V, 24 V)
0
50
Output current (%)
Definition
S8VM
100
17

Related parts for S82Y-VM60D