TXC-03305-MB
Ed. 4, September 2000
M13X
TXC-03305
Address
(cont.)
03
04
05
06
6-0
7-0
7-0
7-0
Bit
DS2OOFn
Symbol
(n=7-1)
(n=7-0)
(n=7-0)
(n=7-0)
CPn
PPn
FBn
DS2 Out of Frame Alarm Indication: A 1 in bits 6-0 corresponds to an Out
Of Frame alarm for the corresponding DS2 channel (7-1). A DS2 OOF
occurs when two out of four consecutive framing bits are in error. A DS2
OOF for a DS2 channel causes AIS to be inserted into its four DS1 chan-
nels when 1TAIS1, 1TAIS0 = 0, 0 or 0, 1 in register 20H, bits 5 and 4.
Recovery to 0 is based on searching for the 0101 framing pattern. Framing
is accomplished by starting at an arbitrary point with the first received bit (0
or 1) and looking 147 (3x49) bit positions later for the bit of opposite sense.
This search is performed for 12 bit positions simultaneously. Once the fram-
ing pattern is found, one more frame is used to acquire alignment. Recov-
ery takes approximately 6.8 milliseconds, worst case average.
FEBE Performance Counter/DS3 F-Bit and M-Bit Error Counter: This
performance counter counts the number of FEBEs received since the last
read cycle in the C-bit parity mode. A FEBE indication occurs when C10,
C11, or C12 is received equal to 0 in a DS3 frame. The counter is protected
during the period of a microprocessor read cycle and when the M13X is
attempting to write to the counter. When this occurs, the incoming error
count indication is held until the counter is read and cleared. Afterwards,
the counter increments. Only the indication of one error count is held during
the microprocessor read and the M13X write cycle. The counter is also
inhibited during DS3 loss of signal or out of frame times. This counter is
cleared when it is read by the microprocessor. In the M13 format mode, this
saturating counter counts the number of DS3 F-bits and M-bits that have
been received in error. This counter is inhibited when a DS3 OOF occurs
and clears when read. When lead M13X is low, this counter is 16 bits wide
and this address contains the low byte of the counter. The high byte of this
counter is written to the CR register (3EH) when this register is read. When
M13X is high, this counter is 8 bits wide.
C-Bit Parity Performance/Number of Frames Counter: In the C-bit parity
mode, this counter counts the number of C-bit parity errors received since
the last read cycle. In the M13 format mode, it counts the number of DS3
frames since the last read cycle. The counter is protected during the period
of a microprocessor read cycle and when the M13X is attempting to write to
the counter. When this occurs, the incoming error count indication is held
until the counter is read and cleared. Afterwards, the counter increments.
Only the indication of one error count is held during the microprocessor
read and the M13X write cycle. The counter is inhibited during DS3 loss of
signal or out of frame times, and is cleared when it is read by the micropro-
cessor. When lead M13X is low, this counter is 16 bits wide and this
address contains the low byte of the counter. The high byte of this counter
is written to the CR register (3EH) when this register is read. When M13X is
high, this counter is 8 bits wide.
P-Bit Parity Performance Counter: This counter counts the number of
P-bit parity errors received since the last read cycle. This performance
count is valid in either operating mode. The counter is protected during the
period of a microprocessor read cycle and when the M13X is attempting to
write to the counter. When this occurs, the incoming error count indication
is held until the counter is read and cleared. Afterward, the counter incre-
ments. Only the indication of one error count is held during the micropro-
cessor read and the M13X write cycle. The counter is also inhibited during
DS3 loss of signal or out of frame times. This counter is cleared when it is
read by the microprocessor. When lead M13X is low, this counter is 16 bits
wide and this address contains the low byte of the counter. The high byte of
this counter is written to the CR register (3EH) when this register is read.
When M13X is high, this counter is 8 bits wide.
DATA SHEET
- 72 -
Description