PIC16LF1847T-I/SO Microchip Technology, PIC16LF1847T-I/SO Datasheet - Page 277

no-image

PIC16LF1847T-I/SO

Manufacturer Part Number
PIC16LF1847T-I/SO
Description
14 KB Flash, 1K Bytes RAM, 32 MHz Int. Osc, 16 I/0, Enhanced Mid Range Core, Nan
Manufacturer
Microchip Technology
Series
PIC® XLP™ mTouch™ 16Fr
Datasheet

Specifications of PIC16LF1847T-I/SO

Core Processor
PIC
Core Size
8-Bit
Speed
32MHz
Connectivity
I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
15
Program Memory Size
14KB (8K x 14)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
18-SOIC (0.295", 7.50mm Width)
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
25.6.13.2
During a Repeated Start condition, a bus collision
occurs if:
a)
b)
When the user releases SDAx and the pin is allowed to
float high, the BRG is loaded with SSPxADD and
counts down to zero. The SCLx pin is then deasserted
and when sampled high, the SDAx pin is sampled.
FIGURE 25-36:
FIGURE 25-37:
 2011 Microchip Technology Inc.
A low level is sampled on SDAx when SCLx
goes from low level to high level.
SCLx goes low before SDAx is asserted low,
indicating that another master is attempting to
transmit a data ‘1’.
SDAx
SCLx
BCLxIF
RSEN
S
SSPxIF
SDAx
SCLx
RSEN
BCLxIF
S
SSPxIF
Bus Collision During a Repeated
Start Condition
BUS COLLISION DURING A REPEATED START CONDITION (CASE 1)
BUS COLLISION DURING REPEATED START CONDITION (CASE 2)
SCLx goes low before SDAx,
set BCLxIF. Release SDAx and SCLx.
Preliminary
T
BRG
Sample SDAx when SCLx goes high.
If SDAx = 0, set BCLxIF and release SDAx and SCLx.
If SDAx is low, a bus collision has occurred (i.e., another
master is attempting to transmit a data ‘0’,
If SDAx is sampled high, the BRG is reloaded and
begins counting. If SDAx goes from high-to-low before
the BRG times out, no bus collision occurs because no
two masters can assert SDAx at exactly the same time.
If SCLx goes from high-to-low before the BRG times
out and SDAx has not already been asserted, a bus
collision occurs. In this case, another master is
attempting to transmit a data ‘1’ during the Repeated
Start condition, see
If, at the end of the BRG time-out, both SCLx and SDAx
are still high, the SDAx pin is driven low and the BRG
is reloaded and begins counting. At the end of the
count, regardless of the status of the SCLx pin, the
SCLx pin is driven low and the Repeated Start
condition is complete.
PIC16(L)F1847
Figure
T
Cleared by software
BRG
25-36.
Interrupt cleared
by software
’0’
’0’
DS41453B-page 277
’0’
Figure
25-35).

Related parts for PIC16LF1847T-I/SO