M41T83SQA6F STMicroelectronics, M41T83SQA6F Datasheet - Page 44

IC RTC SERIAL W/BATT SW 16QFN

M41T83SQA6F

Manufacturer Part Number
M41T83SQA6F
Description
IC RTC SERIAL W/BATT SW 16QFN
Manufacturer
STMicroelectronics
Type
Clock/Calendar/Alarmr
Datasheet

Specifications of M41T83SQA6F

Memory Size
32B
Time Format
HH:MM:SS:hh (24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QFN
Clock Format
12Hr / 24Hr
Clock Ic Type
RTC
Interface Type
I2C, Serial
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
QFN
No. Of Pins
16
Rohs Compliant
Yes
For Use With
497-10833 - DAUGHTER-CARD M41T83SQA6E QFN16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6887-2
M41T83SQA6F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T83SQA6F
Manufacturer:
STMicroelectronics
Quantity:
1 840
Part Number:
M41T83SQA6F
Manufacturer:
Maxim
Quantity:
20
Part Number:
M41T83SQA6F
Manufacturer:
ST
0
Company:
Part Number:
M41T83SQA6F
Quantity:
55
Clock operation
3.15
3.16
Table 17.
1. All other control bits power-up in an undetermined state.
2. M41T83 only
3. BMB0-BMB4, RB0, RB1
4. With battery backup
5. UC = unchanged
Table 18.
1. All other control bits power-up in an undetermined state.
2. M41T83 only
3. With battery backup
4. UC = unchanged
44/61
Initial
power-up
Subsequent
power-up
Initial
power-up
Subsequent
power-up
Condition
Condition
(4)(5)
(3)(4)
(1)
(1)
FT/RST pin, frequency test and reset output pin (M41T82
only)
On the M41T82, the 512 Hz frequency test signal and the reset output share the same pin,
FT/RST. When the FT bit (bit 6 of register 08h) is a 1, the 512 Hz test signal is activated on
the pin. With FT a 0 and V
enabled when V
At power-up, FT will be 0 leaving the pin functioning as the reset output.
Initial power-on defaults
Upon initial application of power to the device, the register bits will initially power-on in the
state indicated in
Initial power-on default values (part 1)
Initial power-up default values (part 2)
RPT11
UC
ST CB1 CB0 OUT FT
0
-15
UC
0
UC
0
HT OF TE
1
1
UC
0
UC
1
CC
Table 17
UC
fails, the FT bit will be cleared and the output will go low to assert reset.
1
0
0
TI/TP
0
0
UC
(2)
CC
0
and
DCS
ACS
UC
good (above V
Doc ID 12578 Rev 12
0
Table
TIE
UC
0
Digital
(2)
calib.
UC
0
18.
TD1 TD0 RS0 RS1-3
UC
1
Analog
calib.
RST
UC
UC
0
1
), the output will be high. If the 512 Hz is
UC
1
OFIE
UC
0
(2)
UC
0
Watch-
dog
0
0
OTP
UC
(3)
(2)
0
A1IE
A2IE
UC
UC
0
0
(2)
(2)
M41T82-M41T83
SQWE
RPT21-
UC
25
UC
0
1
(2)
AL2E
ABE
UC
UC
0
0