ISL12027IBZ Intersil, ISL12027IBZ Datasheet - Page 21

no-image

ISL12027IBZ

Manufacturer Part Number
ISL12027IBZ
Description
IC RTC/CAL W/EEPROM 8-SOIC
Manufacturer
Intersil
Type
Clock/Calendar/Supervisor/EEPROMr
Datasheet

Specifications of ISL12027IBZ

Memory Size
4K (512 x 8)
Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SIGNALS FROM
SIGNALS FROM
THE MASTER
SDA BUS
FIGURE 23. CURRENT ADDRESS READ SEQUENCE
THE SLAVE
FIGURE 24. ACKNOWLEDGE POLLING SEQUENCE
ISSUE MEMORY ARRAY SLAVE
CYCLE COMPLETE. CONTINUE
AFH (READ) OR AEH (WRITE)
COMMAND SEQUENCE?
ENTER ACK POLLING
NON-VOLATILE WRITE
NORMAL READ OR
WRITE COMMAND
COMPLETED BY
ADDRESS BYTE
ISSUING STOP.
ISSUE START
BYTE LOAD
RETURNED?
SEQUENCE
CONTINUE
PROCEED
ACK
A
R
S
T
T
1
YES
YES
ADDRESS
SLAVE
21
1
1
1
NO
NO
1
A
C
K
ISSUE STOP
ISSUE STOP
DATA
ISL12027, ISL12027A
O
S
P
T
Random Read
Random read operations allow the master to access any
location in the ISL12027. Prior to issuing the Slave Address
Byte with the R/W bit set to zero, the master must first
perform a “dummy” write operation.
The master issues the start condition and the slave address
byte, receives an acknowledge, then issues the word
address bytes. After acknowledging receipt of each word
address byte, the master immediately issues another start
condition and the slave address byte with the R/W bit set to
one. This is followed by an acknowledge from the device and
then by the 8 bit data word. The master terminates the read
operation by not responding with an acknowledge and then
issuing a stop condition. Refer to Figure 25 for the address,
acknowledge, and data transfer sequence.
In a similar operation called “Set Current Address,” the
device sets the address if a stop is issued instead of the
second start shown in Figure 25. The ISL12027 then goes
into standby mode after the stop and all bus activity will be
ignored until a start is detected. This operation loads the new
address into the address counter. The next Current Address
Read operation will read from the newly loaded address.
This operation could be useful if the master knows the next
address it needs to read, but is not ready for the data.
Sequential Read
Sequential reads can be initiated as either a current address
read or random address read. The first data byte is
transmitted as with the other modes; however, the master
now responds with an acknowledge, indicating it requires
additional data. The device continues to output data for each
acknowledge received. The master terminates the read
operation by not responding with an acknowledge and then
issuing a stop condition.
The data output is sequential, with the data from address n
followed by the data from address n + 1. The address
counter for read operations increments through all page and
column addresses, allowing the entire memory contents to
be serially read during one operation. At the end of the
address space the counter “rolls over” to the start of the
address space and the ISL12027 continues to output data
for each acknowledge received. Refer to Figure 26 for the
acknowledge and data transfer sequence.
August 12, 2010
FN8232.8

Related parts for ISL12027IBZ