MAX1184ECM+TD Maxim Integrated Products, MAX1184ECM+TD Datasheet - Page 9

IC ADC 10BIT 20MSPS DL 48-TQFP

MAX1184ECM+TD

Manufacturer Part Number
MAX1184ECM+TD
Description
IC ADC 10BIT 20MSPS DL 48-TQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1184ECM+TD

Number Of Bits
10
Sampling Rate (per Second)
20M
Data Interface
Parallel
Number Of Converters
2
Power Dissipation (max)
150mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFP Exposed Pad, 48-eTQFP, 48-HTQFP, 48-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(V
2, 6, 11, 14, 15
3, 7, 10, 13, 16
DD
= 3V, OV
Dual 10-Bit, 20Msps, 3V, Low-Power ADC with
PIN
12
17
18
19
20
1
4
5
8
9
DD
2.015
2.010
2.005
2.000
1.995
1.990
= 2.5V, V
-40
_______________________________________________________________________________________
Internal Reference and Parallel Outputs
INTERNAL REFERENCE VOLTAGE
SLEEP
NAME
COM
INA+
INB+
GND
INA-
INB-
CLK
V
T/B
PD
OE
-15
DD
REFIN
vs. TEMPERATURE
TEMPERATURE (°C)
= 2.048V, differential input at -0.5dBFS, f
10
Common-Mode Voltage Input/Output. Bypass to GND with a ≥ 0.1µF capacitor.
Analog Supply Voltage. Bypass each pin to GND with a 0.1µF capacitor. The analog supply
accepts an input range of 2.7V to 3.6V.
Analog Ground
Channel A Positive Analog Input. For single-ended operation, connect signal source to INA+.
Channel A Negative Analog Input. For single-ended operation, connect INA- to COM.
Channel B Negative Analog Input. For single-ended operation, connect INB- to COM.
Channel B Positive Analog Input. For single-ended operation, connect signal source to INB+.
Converter Clock Input
T/B selects the ADC digital output format.
High: Two’s complement.
Low: Straight offset binary.
Sleep Mode Input.
High: Deactivates the two ADCs, but leaves the reference bias circuit active.
Low: Normal operation.
Power-Down Input.
High: Power-down mode
Low: Normal operation
Output Enable Input.
High: Digital outputs disabled
Low: Digital outputs enabled
35
60
Typical Operating Characteristics (continued)
85
CLK
70,000
63,000
56,000
49,000
42,000
35,000
28,000
21,000
14,000
= 20MHz, C
7,000
0
FUNCTION
OUTPUT NOISE HISTOGRAM (DC INPUT)
N-2
0
L
≈ 10pF, T
869
N-1
DIGITAL OUTPUT CODE
64,515
N
A
= +25°C, unless otherwise noted.)
N+1
152
Pin Description
N+2
0
9

Related parts for MAX1184ECM+TD