EP2SGX30DF780I4N Altera, EP2SGX30DF780I4N Datasheet - Page 172

IC STRATIX II GX 30K 780-FBGA

EP2SGX30DF780I4N

Manufacturer Part Number
EP2SGX30DF780I4N
Description
IC STRATIX II GX 30K 780-FBGA
Manufacturer
Altera
Series
Stratix® II GXr
Datasheet

Specifications of EP2SGX30DF780I4N

Number Of Logic Elements/cells
33880
Number Of Labs/clbs
1694
Total Ram Bits
1369728
Number Of I /o
361
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2177

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2SGX30DF780I4N
Manufacturer:
ALTERA
Quantity:
996
Part Number:
EP2SGX30DF780I4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2SGX30DF780I4N
Manufacturer:
ALTERA
0
Part Number:
EP2SGX30DF780I4N
Manufacturer:
ALTERA
Quantity:
50
Part Number:
EP2SGX30DF780I4N
Manufacturer:
ALTERA
Quantity:
20 000
Operating Conditions
4–2
Stratix II GX Device Handbook, Volume 1
V
V
V
V
V
Table 4–3. Stratix II GX Device Recommended Operating Conditions (Part 1 of 2)
Symbol
CCINT
CCIO
CCPD
I
O
Supply voltage for internal logic
and input buffers
Supply voltage for output
buffers, 3.3-V operation
Supply voltage for output
buffers, 2.5-V operation
Supply voltage for output
buffers, 1.8-V operation
Supply voltage for output
buffers, 1.5-V operation
Supply voltage for output
buffers, 1.2-V operation
Supply voltage for pre-drivers as
well as configuration and JTAG
I/O buffers.
Input voltage (see
Output voltage
Parameter
Recommended Operating Conditions
Table 4–3
operating conditions.
Table
Note to
(1)
Table 4–2. Maximum Duty Cycles in Voltage Transitions
Symbol
During transition, the inputs may overshoot to the voltages shown based on the
input duty cycle. The duty cycle case is equivalent to 100% duty cycle.
V
4–2)
I
Table
contains the Stratix II GX device family recommended
Maximum duty cycles
in voltage transitions
4–2:
100 μs ≤ rise time ≤ 100 ms
100 μs ≤ rise time ≤ 100 ms (3),
100 μs ≤ rise time ≤ 100 ms
100 μs ≤ rise time ≤ 100 ms
100 μs ≤ rise time ≤ 100 ms
100 μs ≤ rise time ≤ 100 ms
100 μs ≤ rise time ≤ 100 ms
(2),
(5)
Parameter
Conditions
Condition
V
V
V
V
V
V
(3)
(3)
(3)
(3)
(3)
(4)
I
I
I
I
I
I
= 4.0 V
= 4.1 V
= 4.2 V
= 4.3 V
= 4.4 V
= 4.5 V
(6)
Minimum
(3.00)
3.135
2.375
1.425
3.135
1.15
1.71
1.15
–0.5
0
Maximum Duty Cycles
Note (1)
Altera Corporation
Maximum Unit
(%)
(3.60)
3.465
2.625
1.575
3.465
V
1.25
1.89
1.25
100
90
50
30
17
10
4.0
CCIO
(1)
June 2009
V
V
V
V
V
V
V
V
V

Related parts for EP2SGX30DF780I4N