2.5 Starting Dynamic C
Once the Intellicom is connected to your PC and to a power source,
clicking on the Dynamic C
If you are using a USB port to connect your computer to the Intellicom, choose
Project Options
Dynamic C defaults to using the serial port on your PC that you specified during installa-
tion. If the port setting is correct, Dynamic C should detect the Intellicom and go through
a sequence of steps to cold-boot the Intellicom and to compile the BIOS. (Some versions
of Dynamic C will not do the initial BIOS compile and load until the first time you com-
pile a program.)
If you receive the message
cable may be connected to the wrong COM port, a connection may be faulty, or the target
system may not be powered up. First, check both ends of the programming cable to ensure
that it is firmly plugged into the PC and the programming port with the marked (colored)
edge of the programming cable towards pin 1 of the programming header.
If there are no faults with the hardware, select a different COM port within Dynamic C.
From the
then click OK. Press
still reports it is unable to locate the target system, repeat the above steps until you locate the
active COM port. You should receive a
once this step is completed successfully.
If Dynamic C appears to compile the BIOS successfully, but you then receive a communi-
cation error message when you compile and load a sample program, it is possible that your
PC cannot handle the higher program-loading baud rate. Try changing the maximum
download rate to a slower baud rate as follows.
• Locate the
If a program compiles and loads, but then loses target communication before you can
begin debugging, it is possible that your PC cannot handle the default debugging baud
rate. Try lowering the debugging baud rate as follows.
• Locate the
14
menu. Select a slower Max download baud rate.
menu. Choose a lower debug baud rate.
Options
Serial Options
Serial Options
and select “Use USB to Serial Converter.” Click
menu, select
<Ctrl-Y>
icon on your desktop or in your
No Rabbit Processor Detected
dialog in the Dynamic C
dialog in the Dynamic C
to force Dynamic C to recompile the BIOS. If Dynamic C
Communications
Bios compiled successfully
. Select another COM port from the list,
Options > Communications
Options > Communications
Start
menu
Intellicom (OP6600/OP6700)
start Dynamic C by double-
, the programming
OK
.
.
message
Options >