E5AN-C3MT-500-N AC100-240 Omron, E5AN-C3MT-500-N AC100-240 Datasheet

no-image

E5AN-C3MT-500-N AC100-240

Manufacturer Part Number
E5AN-C3MT-500-N AC100-240
Description
Controllers Multi input 1/4 Din TC New08
Manufacturer
Omron
Datasheet

Specifications of E5AN-C3MT-500-N AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series.
Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H).
• Improved indication accuracy and preventive maintenance (Basic Type E5@N).
• New high-performance Controllers (Advanced Type E5@N-H).
• Easy-to-use one-touch operation with PF Key (Only for 1/8 and 1/4 DIN).
• Logic operations.
Digital Temperature Controllers/Digital Controllers
E5@N/E5@N-H
1/16 DIN
E5CN
Basic Type (Renewal E5@N)
1/8 DIN
E5EN
1/4 DIN
E5AN
E5@N Series
1/16 DIN
E5CN-H
Advanced Type (New E5@N-H)
E5EN-H
1/8 DIN
E5AN-H
1/4 DIN
1 1

E5AN-C3MT-500-N AC100-240 Summary of contents

Page 1

... Easy-to-use one-touch operation with PF Key (Only for 1/8 and 1/4 DIN). • Logic operations. Basic Type (Renewal E5@N) E5CN E5EN 1/16 DIN 1/8 DIN E5@N Series Advanced Type (New E5@N-H) E5AN E5CN-H 1/4 DIN 1/16 DIN E5EN-H E5AN-H 1/8 DIN 1/4 DIN 1 1 ...

Page 2

... Digital Temperature Controllers Digital Controllers Operation Procedure Common to All Controllers CX-Thermo Support Software 2 Contents E5CN/E5CN-U ............................................. E5AN/E5EN ................................................. E5CN-H........................................................ E5AN-H/E5EN-H.......................................... • Operation ..................................................... • Safety Precautions ....................................... • EST2-2C-MV4.............................................. ...

Page 3

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) ( mm) 48 ...

Page 4

E5CN/E5CN-U Lineup Terminal block E5CN Basic Type Plug-in Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5CN-@@M@@-@-500 ...

Page 5

Ordering Information Controllers with Terminal Blocks Power supply Size Case color voltage 100 to 240 VAC 24 VAC/VDC Black 1/16 DIN 100 to 240 VAC ( VAC/VDC 100 to 240 VAC Silver 24 VAC/VDC ...

Page 6

E5CN/E5CN-U Model Number Structure Model Number Legend (Plug-in-type Controllers) E5CN-@@@ Output Type R: Relay output Q: Voltage output (for driving SSR) C: Current output 2. Number of Alarms Blank: No alarm 1: One alarm 2: ...

Page 7

Accessories (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models Terminal block models Model E53-COV17 Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Model Y92S-29 Note: The Waterproof Packing is included with the Controller only ...

Page 8

E5CN/E5CN-U Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 9

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Input Platinum resistance Type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 10

E5CN/E5CN-U Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 11

... When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s). ✽6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time. ✽7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11 is not certified for UL listing. ...

Page 12

... E5CN/E5CN-U USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version 4.0 or Applicable software higher E5AN/E5EN/E5CN/E5CN-U/E5AN-H/ Applicable models E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector Temperature Controller: Setup Tool port ...

Page 13

... Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose. E5CN ...

Page 14

E5CN/E5CN-U Nomenclature E5CN E5CN-U The front panel is the same for the E5CN and E5CN-U. Operation indicators Dimensions E5CN Terminal Models 48 48 E5CN-U Plug-in Models 48 48 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 14 Temperature unit Level Key ...

Page 15

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 16

E5CN/E5CN-U Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN E5CN-U Wiring Socket Front-connecting Socket Eleven, M3.5 P2CF-11 sems screws 70 max max. Note: A model with finger ...

Page 17

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) ...

Page 18

... E5AN/E5EN Terminal block Basic Type Note: Models with one control output or two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5AN/E5EN-@3@M@@-@-500 Control Output 1 R: Relay output Q: Voltage output (for driving SSR) C: Current output 2 ...

Page 19

... Voltage E5AN-R3QMT-500-N output Voltage E5AN-Q3QMT-500-N output Voltage E5AN-C3QMT-500-N output E5AN-R3YMT-500-N Long-life relay E5AN-Q3YMT-500-N output E5AN-C3YMT-500-N E5AN-R3PMT-500-N E5AN-Q3PMT-500-N E5AN-R3ML-500-N E5AN-Q3ML-500-N E5AN-C3ML-500-N E5AN-R3HML-500-N E5AN-Q3HML-500-N Long-life relay E5AN-Q3YML-500-N output E5AN-R3MTD-500-N E5AN-Q3MTD-500-N E5AN-C3MTD-500-N E5AN-R3HMTD-500-N E5AN-Q3HMTD-500-N E5AN-R3HHMTD-500-N E5AN-Q3HHMTD-500-N E5AN-R3MT-W-500-N E5AN-Q3MT-W-500-N E5AN-C3MT-W-500-N E5AN-R3HMT-W-500-N E5AN-Q3HMT-W-500-N E5AN-R3MTD-W-500-N E5AN-Q3MTD-W-500-N E5AN-C3MTD-W-500-N 19 ...

Page 20

... E5AN/E5EN E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN Analog (current/volt- age) Thermocouple 24 VAC/ or VDC Resistance thermometer 100 to 240 VAC Thrmocouple or Silver Resistance thermometer 24 VAC/ VDC 20 Functions ...

Page 21

... Note: The Waterproof Packing is included with the Controller. Function RS-232C communications RS-485 communications Event inputs Current Transformers (CTs) Hole diameter 5.8 dia. 12.0 dia. CX-Thermo Support Software Model Model Y92S-P4 Y92S-P5 E5AN/E5EN Model E53-EN01 E53-EN03 E53-AKB Model E54-CT1 E54-CT3 Model EST2-2C-MV4 21 ...

Page 22

... Setting method Digital setting using front panel keys 11-segment digital display and individual indicators (7-segments displays also possible) Character height: E5AN: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN: PV: 11.8 mm, SV: 8.1 mm, Indication method Content of 3-level display: PV/SV/MV, PV/SV/multi-SP, or soak time remain ✽ ...

Page 23

... JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) Voltage E5AN/E5EN Infrared temperature sensor 115 140 120 165 260 2300 1800 1300 260 120 ...

Page 24

... E5AN/E5EN Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent ...

Page 25

... Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.0 or higher Provided on the bottom of the E5AN and E5EN. Setup Tool port An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN and E5EN ✽6 Approved UL 61010-1, CSA C22.2 No. 1010-1 standards Standards ...

Page 26

... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN/E5EN 100 250 VAC, 30 VDC (resistive load) cos = ...

Page 27

... VDC CT2 DO NOT - 16 USE DO NOT USE DO NOT 17 USE A DO NOT DO NOT 18 USE USE NOT B 20 USE TC/Pt multi-input Analog input E5AN/E5EN Communications E53-EN01 E53-EN03 E53-AKB RS-232C RS-485 Event inputs EV2 NOT USE CT1/CT2 A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned ...

Page 28

... Auto/Manual Key E5AN Level Key ✽ A 2-level display when shipped from the factory. A 3-level display is activated if parameters are initialized. For details on the third display level, refer to the User’s Manual, Basic Type (Cat. No. H156). Dimensions E5AN 112 96 96 Waterproof Packing (Accessory) ...

Page 29

... Terminal Cover (E53-COV16) Waterproof Mounting Bracket (Accessory) Packing (Accessory) (Accessory) Crimp terminal size: M3.5 250 LED (SD) 1.2 3.2 10 44.8 E5AN/E5EN Mounted Separately Group Mounted (48 number of units +0 Group mounting does not 120 min. allow waterproofing. +0 • Recommended panel thickness mm. • Group mounting is not possible in the vertical direction. ...

Page 30

... E5AN/E5EN Waterproof Packing Y92S-P4 (for DIN 96 96) Y92S-P5 (for DIN 48 Current Transformers E54-CT1 E54-CT3 E54-CT3 Accessory Armature Connection Example Approx. 3 dia. 18 Plug Approx. 6 dia. (22) 30 96) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection ...

Page 31

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159) ( mm) E5CN-H ...

Page 32

E5CN-H Lineup E5CN-H Terminal block Advanced Type Note: Models with one control output and models with two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5CN-@@@M@-@-500 ...

Page 33

Ordering Information Controllers Size Case Color Power supply voltage 100 to 240 VAC Black 24 VAC/VDC 1/16 DIN 100 to 240 VAC Silver 24 VAC/VDC Option Units One of the following Option Units can ...

Page 34

E5CN-H Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 35

Input Ranges Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs) Platinum resistance Input type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500.0 500 400 300 200.00 ...

Page 36

E5CN-H Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 37

Characteristics Thermocouple: ( 0.1% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.1% FS ...

Page 38

... USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/ Applicable models E5AN-H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector specifications Temperature Controller: Setup Tool ...

Page 39

External Connections A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals are ...

Page 40

E5CN-H Nomenclature E5CN-H Operation indicators Dimensions E5CN Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 40 Temperature unit SUB1 SUB2 SUB3 HA OUT1 STOP OUT2 CWM MANU Level Key E5CN-H Mode Key Down Key 1.5 58 ...

Page 41

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 42

E5CN-H Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN-H 42 4.7 76 69 Panel ( mm 2.2 4.7 77.3 ...

Page 43

... SSR outputs • Relay output • Voltage output (for driving SSR) • Current output • Linear voltage output E5AN-H E5EN-H Refer to Safety Precautions on page 66. • Auto/manual switching • Temperature Controller Auxiliary Outputs status display • Two • Simple program • Three function • ...

Page 44

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159) 44 Fully universal input ...

Page 45

... E5AN-HAA2HBMD-500 input 4 to 20-mA E5AN-HSS2HBMD-500 input 4 to 20-mA E5AN-HAA2HHBFMD-500 input 4 to 20-mA E5AN-HSS2HHBFMD-500 input 4 to 20-mA E5AN-HAA3BFMD-500 input 4 to 20-mA E5AN-HSS3BFMD-500 input 4 to 20-mA E5AN-HPRR2BMD-500 input 4 to 20-mA E5AN-HPRR2BFMD-500 input 4 to 20-mA E5AN-HAA2HBM-W-500 input 4 to 20-mA E5AN-HAA2HHBFM-W-500 input 4 to 20-mA E5AN-HAA2HBMD-W-500 ...

Page 46

... E5EN-HPRR2BMD-500 input 4 to 20- 20-mA 2 E5EN-HPRR2BFMD-500 output input 4 to 20-mA 2 E5EN-HAA2HBM-W-500 input 4 to 20- 20-mA 2 E5EN-HAA2HHBFM-W-500 output input 4 to 20-mA 2 E5EN-HAA2HBMD-W-500 input Model E58-CIFQ1 Model E5AN-H E53-COV16 E5EN-H Model E5AN-H Y92S-P4 E5EN-H Y92S-P5 Model 5.8 dia. E54-CT1 12.0 dia. E54-CT3 Model EST2-2C-MV4 ...

Page 47

... Set digitally using keys on the front panel or by using the RSP input. 11-segment digital display and individual indicators (7-segments displays also possible) Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm Indication method Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain ...

Page 48

... E5AN-H/E5EN-H Input Ranges Thermocouple/Platinum Resistance Thermometer (Fully Universal Inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500 400 300 200.00 200 100.0 100 ...

Page 49

... Set value: 5, Upper- and lower-limit with standby sequence ON OFF Always OFF when the upper-limit and lower-limit hysteresis 0 overlaps ✽6. Displayed when there is a remote SP input. OFF OFF OFF OFF OFF 0 E5AN-H/E5EN-H Case 2 Case 3 (Always ON) H < < < > > < > > < Case 2 Case 3 (Always ON) H < < ...

Page 50

... Provided on the bottom of the E5AN-H and E5EN-H. An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN-H and E5EN-H. Setup Tool port Provided on the front of the E5AN-H and E5EN-H. An E58-CIFIR USB-infrared Conversion Cable is required to connect the computer to the E5AN-H or E5EN-H. ✽4 Approved UL 61010-1, CSA C22 ...

Page 51

... Plugs (2) USB-Infrared Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher Applicable models E5AN-H/E5EN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector specifications Temperature Controller: Infrared port (on front of Controller) ...

Page 52

... E5AN-H/E5EN-H Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN-H/E5EN-H 100 250 VAC, 30 VDC (resistive load) cos = Switching current (A) 52 SSR Outputs (OUT1/OUT2) Ratings Rated load voltage 250 VAC Rated load current (resistive load) Note: 1. The load current must be within the derating curve. ...

Page 53

... USE A DO NOT DO NOT USE USE NOT USE (Load: 600 max E5AN-H/E5EN-H Communications E53-EN03 E53-AKB RS-485 Event Inputs RDB EV2 12 12 RDA EV1 NOT USE SDB SDA Auxiliary output 3 Relay output SPDT, 250 VAC (resistive load) DO NOT USE A heater burnout alarm, SSR ...

Page 54

... Temperature unit SUB1 SUB2 SUB3 Operation indicators HA OUT1 RSP STOP OUT2 CMW MANU Programmable PF Function Key/ A/M Auto/Manual Key E5AN-H Level Key Dimensions E5AN 112 Waterproof Packing (Accessory) 54 E5EN-H Operation indicators PV No.1 display SV No.2 display MV No.3 display Operation indicators Up Key Ir Down Key ...

Page 55

... E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 120 min. E5AN-H/E5EN-H Group Mounted✽ +1.0 (48 × number of units − 2. Group mounting does not allow waterproofing. ...

Page 56

... E5AN-H/E5EN-H Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable USB connector (type A plug) Mounting Adapter USB-Serial Conversion Cable E58-CIFQ1 Terminal Covers E53-COV16 (Six Covers provided.) 56 (2,000) With Mounting Adapter Connected 39 16 18.5 Mounting Adapter (Accessory) 99.2 23.1 21.8 (75) ...

Page 57

... Two, 3.5 dia. 2.36 dia. 12 dia. 9 Two, M3 (depth 4) Armature Lead E5AN-H/E5EN-H E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current (50/60 Hz) Number of windings: 400 2 Winding resistance 100 Distortion 1 k factor 10% ...

Page 58

... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). ✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...

Page 59

... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). ✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...

Page 60

... E5@N/E5@N-H Parameters Basic Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). Press the PF Key for at least 1 s. ✽1 Press the O Key less than 1 s. ...

Page 61

... Assignment on alm1 M M Auxiliary Output 2 pvst PV Status Display Assignment Function off alm2 M M svst SV Status Display Auxiliary Output 3 Assignment Function alm3 off (E5AN/E5EN only d.ref Display Refresh Character Select Period 0. ra1m t-u Control Output 1 Soak Time Unit ON/OFF Count 0 m Monitor M M ...

Page 62

... E5@N/E5@N-H Advanced Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display PID Selection d.pid PID1 1 d.pid ...

Page 63

... Extraction of Square Root 0.0 Low-cut Point M ✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H). ✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H). Power ON Starting in manual mode. Manual Control Level Press the O PID 25 ...

Page 64

... Setting Change Protect: Protects changes to setups off by operating the front panel keys. M pfpt PF Key Protect Restricts PF key operation off (E5AN-H/E5EN-H only) M pmsk Parameter Mask Enable: Displayed only when a on parameter mask is set. M prlp Password to Move to Protect Level: 0 ...

Page 65

... Assignment alm1 M M ocu Heater Overcurrent sub2 Auxiliary Output 2 Assignment on Use alm2 M M ocl Heater Overcurrent sub3 Auxiliary Output 3 Assignment Latch off alm3 (E5AN/E5EN-H only och Heater Overcurrent csel Character Select Hysteresis 0 t-u PF Setting Soak Time Unit a E5@N/E5@N-H Monitor/Setting Item Level ...

Page 66

E5@N/E5@N-H Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings ...

Page 67

... Do not use an extension cable to extend the Conversion Cable length when connecting to the computer. Doing so may damage the Conversion Cable. 6. The E5AN-H/E5EN-H use the same port for communications through the infrared port and the Support Software port. Do not attempt to use communications through the Support Software port when the infrared port is being used ...

Page 68

... The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads. This is possible for only the E5CN, E5AN, and E5EN, and not for the E5CN-U. Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case. ...

Page 69

... E5AN/E5EN toward the rear case until it snaps into position. While pressing the E5AN/E5EN into place, press down on the hooks on the top and bottom surfaces of the rear case so that the hooks securely lock in place ...

Page 70

... CX-Thermo Support Software Ver. 4.0 EST2-2C-MV4 Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H, E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling Faster Parameter Setup, Device Adjustment, and Maintenance Enables editing and batch-downloading parameters from a personal computer, reducing the work required to set parameters. ...

Page 71

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 72

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...