E5AN-C3MT-500-N AC100-240 Omron, E5AN-C3MT-500-N AC100-240 Datasheet - Page 61

no-image

E5AN-C3MT-500-N AC100-240

Manufacturer Part Number
E5AN-C3MT-500-N AC100-240
Description
Controllers Multi input 1/4 Din TC New08
Manufacturer
Omron
Datasheet

Specifications of E5AN-C3MT-500-N AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Press the O Key for at least 1 s.
C
C
alh3
alh2
alt3
tr-h
ev-m
ev-1
ev-2
alt2
amov
tr-t
tr-l
o1-t
100.0
4-20
none
stop
sqr
off
off
Move by setting password ( 169).
M
M
M
M
M
M
M
M
M
M
M
0.2
0.2
0.0
M
2
2
1
0
Transfer Output
Lower Limit
Alarm 2 Type
Alarm 2
Hysteresis
Alarm 3 Type
Transfer Output Type
Transfer Output
Upper Limit
Linear Current Output
Number of Multi-SP Uses
Two SPs: 1
Four SPs: 2
Extraction of Square
Root Enable
Move to Advanced
Function Setting Level:
Displayed when initial
setting/communications
protect is set to 0.
Event Input
Assignment 1
Alarm 3
Hysteresis
Event Input
Assignment 2
Linear output
Monitor/Setting Item Level
Linear output
C
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).
25
0
Monitor/Setting
Item Display 1
PF
Advanced Function Setting Level
C
C
rest
sb3n
at-h
init
mspu
spru
sb1n
sb2n
at-g
lcma
pvad
o-dp
alfa
st-b
hbu
hbh
inf
ret
hbl
15.0
20.0
0.65
off
off
n-o
n-o
n-o
off
off
off
M
M
M
M
M
M
M
M
off
M
0.1
M
M
M
0.8
M
0.8
M
M
0.0
M
M
on
M
M
a
m
Parameter Initialization
Standby Sequence
Reset
Heater Burnout Latch
Heater Burnout
Hysteresis
ST Stable Range
AT Calculated Gain
Automatic Display
Return Time
Multi-SP Uses
SP Ramp Time Unit
Auxiliary Output 1
Open in Alarm
Auxiliary Output 2
Open in Alarm
HB ON/OFF
AT Hysteresis
Limit Cycle MV
Amplitude
Input Digital Filter
Additional PV Display
Auxiliary Output 3
Open in Alarm
MV Display
Monitor/Setting
Item Display 2
(E5AN/E5EN only)
PF
C
a2on
a3on
a1of
istp
amad
colr
a2of
a3of
a1on
mvse
rlrv
pv-b
a1lt
sero
a3lt
prlt
a2lt
ins1
cjc
off
red
off
off
off
off
off
M
M
off
M
M
5.0
M
M
M
M
M
M
M
M
rt
M
off
M
M
M
M
M
M
on
0
0
0
0
0
0
3
Alarm 3 ON Delay
Auto/Manual Select
Addition
PV Change Color
PV Stable Band
Alarm 2 ON Delay
Input Shift Type
Alarm 1 Latch
Move to Protect Level
Time
Alarm 1 ON Delay
Alarm 1 OFF Delay
Alarm 2 OFF Delay
Alarm 3 OFF Delay
MV at Stop and Error
Addition
RT
Input Error Output
Cold Junction
Compensation
Method
MB Command
Logic Switching
Alarm 3 Latch
Alarm 2 Latch
Monitor/Setting
Item Display 3
PF
C
C
out1
out2
sub1
lbab
sub2
sub3
lbal
alsp
csel
pvrp
csca
manl
hsu
hsh
lba
none
alm2
hsl
alm1
alm3
t-u
sp-m
ocu
och
M
off
ocl
M
0.1
M
M
8.0
M
3.0
M
M
on
M
off
M
M
M
M
M
M
M
M
off
off
on
M
M
M
o
on
0.1
M
0
m
4
HS Alarm Use
HS Alarm Latch
HS Alarm Hysteresis
LBA Detection Time
LBA Band
LBA Level
Control Output 1
Assignment
Control Output 2
Assignment
Auxiliary Output 1
Assignment
Auxiliary Output 3
Assignment
(E5AN/E5EN only)
Alarm SP Selection
Manual MV
Limit Enable
Auxiliary Output 2
Assignment
Character Select
Soak Time Unit
PV Rate of Change
Calculation Period
Automatic Cooling
Coefficient Adjustment
Heater Overcurrent
Use
Heater Overcurrent
Latch
Heater Overcurrent
Hysteresis
Monitor/Setting
Item Display 4
E5@N/E5@N-H
PF
pfd2
pfd3
pfd4
pfd5
pvdp
pfd1
odsl
d.ref
spdp
ra1m
ra2m
pvst
svst
cmov
ra1
ra2
rac
a-m
0.25
pf
off
off
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
on
M
1
0
0
0
0
4
0
0
0
0
0
o
0
Monitor/Setting Item 2
Monitor/Setting Item 3
Move to Calibration
Level
PF Setting
(E5AN/E5EN only)
Monitor/Setting Item 1
Monitor/Setting Item 4
MV Display Selection
PV Decimal Point
Display
PV Status Display
Function
SV Status Display
Function
Control Output 1
ON/OFF Count
Monitor
Control Output 2
ON/OFF Count
Alarm Set Value
ON/OFF Counter
Reset
Monitor/Setting Item 5
"PV/SP" Display
Screen Selection
Display Refresh
Period
Control Output 2
ON/OFF Count
Monitor
Control Output 1
ON/OFF Count
Alarm Set Value
(E5AN/E5EN only)
Monitor/Setting
Item Display 5
61