E5AN-C3MT-500-N AC100-240 Omron, E5AN-C3MT-500-N AC100-240 Datasheet - Page 26

no-image

E5AN-C3MT-500-N AC100-240

Manufacturer Part Number
E5AN-C3MT-500-N AC100-240
Description
Controllers Multi input 1/4 Din TC New08
Manufacturer
Omron
Datasheet

Specifications of E5AN-C3MT-500-N AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
26
E5AN/E5EN
USB-Serial Conversion Cable
Note: A driver must be installed in the personal computer. Refer to
Communications Specifications
✽ The baud rate, data bit length, stop bit length, and vertical parity can
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating temper-
ature
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
Transmission line
connection method
Communications
Synchronization method Start-stop synchronization
Protocol
Baud rate
Transmission code
Data bit length ✽
Stop bit length ✽
Error detection
Flow control
Interface
Retry function
Communications buffer
Communications
response wait time
be individually set using the Communications Setting Level.
installation information in the operation manual for the
Conversion Cable.
RS-485: Multipoint
RS-232C: Point-to-point
RS-485 (two-wire, half duplex) or RS-
232C
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400,
or 57600 bps
ASCII
7 or 8 bits
1 or 2 bits
Vertical parity (none, even, odd)
Frame check sequence (FCS) with
SYSWAY
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
None
RS-485, RS-232C
None
217 bytes
0 to 99 ms
Default: 20 ms
Windows 2000, XP, or Vista
Thermo Mini, CX-Thermo version
4.0 or higher
E5AN/E5EN/E5CN/E5CN-U/E5AN-
H/E5EN-H/E5CN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Setup Tool
port (on bottom of Controller)
Bus power (Supplied from USB host
controller.)
5 VDC
70 mA
0 to 55°C (with no condensation or
icing)
or icing)
10% to 80%
2,000 m max.
Approx. 100 g
20 to 60°C (with no condensation
Current Transformer (Order Separately)
Ratings
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
✽1. For heater burnout alarms, the heater current will be measured
✽2. For SSR failure alarms, the heater current will be measured when
✽3. For heater overcurrent alarms, the heater current will be
Electrical Life Expectancy Curve for
Relays (Reference Values)
Note: Do not connect a DC load to a Controller with a Long-life Relay
Dielectric strength
Vibration resistance 50 Hz, 98 m/s
Weight
Accessories
(E54-CT3 only)
CT input (for heater cur-
rent detection)
Maximum heater current
Input current indication
accuracy
Heater burnout alarm set-
ting range ✽1
SSR failure alarm setting
range ✽2
Heater overcurrent alarm
setting range ✽3
500
300
100
when the control output is ON, and the output assigned to the
alarm 1 function will turn ON if the heater current is lower than the
set value (i.e., heater burnout detection current value).
the control output is OFF, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set
value (i.e., SSR failure detection current value).
measured when the control output is ON, and the output assigned
to the alarm 1 function will turn ON if the heater current is higher
than the set value (i.e., heater overcurrent detection current
value).
50
30
10
5
3
1
0
Output.
1
2
1,000 VAC for 1 min
E54-CT1: Approx. 11.5 g,
E54-CT3: Approx. 50 g
Armatures (2)
Plugs (2)
3
E5AN/E5EN
250 VAC, 30 VDC
(resistive load)
cos = 1
Switching current (A)
Models with detection for single-
phase heaters: One input
Models with detection for single-
phase or three-phase heaters: Two
inputs
50 A AC
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms
4
5% FS 1 digit max.
5
2
6