Specifications of E5AN-C3MT-500-N AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
34
E5CN-H
Specifications
Ratings
✽ For models with current outputs, control output 1 can be used as a transfer output.
Power supply voltage
Operating voltage range
Power consumption
Sensor input
Input impedance
Control method
Control
output
Auxilia-
ry
output
Event
input
Logic
opera-
tions
Transfer
outputs
RSP input
Setting method
Indication method
Bank switching
Other functions
Ambient operating tempera-
ture
Ambient operating humidity
Storage temperature
Relay output
Voltage output
(for driving SSR)
Current output
Linear voltage out-
put
Number of outputs 2 max.
Output specifica-
tions
Number of outputs 2
External contact
input specifica-
tions
Number of opera-
tions
Operations
Outputs
Work bit assign-
ments
Number of outputs 1 max.
Output
specifications
No D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
85% to 110% of rated supply voltage
100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA)
24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)
Any of the following can be selected (i.e., fully universal input).
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Current input: 150
ON/OFF control or 2-PID control (with auto-tuning)
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
4 to 20 mA DC/0 to 20 mA DC, load: 600
0 to 10 VDC (load: 1 k
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
load: 5 V, 10 mA
Contact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
8 max. (Combinations can be made using work bits.)
One work bit per operation
Any of the following can be assigned to up to eight work bits (logic operation results): Event input operations,
auxiliary outputs, or control outputs.
Current output: 4 to 20 mA DC, Load: 600
Not supported
Digital setting using front panel keys
11-segment digital display and individual indicators (7-segments displays also possible)
Character height: PV: 11 mm, SV: 6.5 mm
Supported (number of banks: 8)
Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV
status display, logic operations, automatic cooling coefficient adjustment
25% to 85%
10 to 55 C (with no condensation or icing), for 3-year warranty: 10 to 50 C
25 to 65 C (with no condensation or icing)
Logic operation: Any of the following four patterns can be selected. The input status may be inverted.
Delay:
Output inversion: Possible
(A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B,
C, and D are four inputs.)
ON delay or OFF delay for the results of the logic operation given above.
Setting time: 0 to 9999 s or 0 to 9999 min
max., Voltage input: 1 M
min.), Resolution: Approx. 10,000
max., resolution: approx. 10,000 ✽
max., Resolution at 4 to 20 mA: Approx. 10,000
min. (Use a 1:1 connection when connecting the ES2-HB.)