E5AN-C3MT-500-N AC100-240 Omron, E5AN-C3MT-500-N AC100-240 Datasheet - Page 65

no-image

E5AN-C3MT-500-N AC100-240

Manufacturer Part Number
E5AN-C3MT-500-N AC100-240
Description
Controllers Multi input 1/4 Din TC New08
Manufacturer
Omron
Datasheet

Specifications of E5AN-C3MT-500-N AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Press the O Key for at least 1 s.
Protect Level
c
c
sb1n
sb3n
alfa
at-g
at-h
lcma
pvad
spru
rest
sb2n
st-b
init
hbu
hbh
inf
hbl
0.65
n-o
n-o
15.0
20.0
off
M
M
M
n-o
M
M
M
M
M
M
off
off
0.1
M
M
M
M
M
0.0
M
M
1.0
0.8
on
m
a
Heater Burnout
Latch
Parameter Initialization
SP Ramp Time Unit
Standby Sequence
Reset
Auxiliary Output 2
Open in Alarm
Auxiliary Output 3
Open in Alarm
Heater Burnout
Hysteresis
ST Stable Range
Auxiliary Output 1
Open in Alarm
Input Digital Filter
HB ON/OFF
AT Calculated Gain
AT Hysteresis
Limit Cycle MV
Amplitude
Additional PV Display
Manual Control
Function Setting
Power ON
Level
Initial Setting
Advanced Function Setting Level
Operation
Advanced
Level
Level
Level
c
sero
colr
a2on
o-dp
a1lt
pv-b
a1on
a3on
a1of
a3of
a2lt
a3lt
prlt
rlrv
a2of
cjc
ret
off
red
off
off
off
off
off
off
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
on
5.0
3
0
0
0
0
0
0
0
Automatic Display
Return Time
Move to Protect Level
Time
PV Change Color
Alarm 1 OFF Delay
Alarm 1 Latch
Input Error Output
MB Command
Logic Switching
PV Stable Band
Alarm 1 ON Delay
Alarm 2 ON Delay
Alarm 2 OFF Delay
MV Display
Cold Junction
Compensation
Method
Alarm 3 ON Delay
Alarm 3 OFF Delay
Alarm 2 Latch
Alarm 3 Latch
Communica-
tions Setting
Adjustment
Level
Level
c
c
sub1
sub2
sub3
istp
amad
out1
out2
mvse
lbab
csel
lbal
alm1
t-u
ins1
lba
alm2
alm3
hsu
hsh
hsl
none
off
off
off
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
rt
M
3.0
on
0.1
8.0
on
on
m
0
o
HS Alarm Hysteresis
LBA Detection Time
Auto/Manual Select
Addition
HS Alarm Use
HS Alarm Latch
Control Output 1
Assignment
Input Shift Type
LBA Level
Control Output 2
Assignment
Auxiliary Output 2
Assignment
Auxiliary Output 3
Assignment
(E5AN/E5EN-H only)
MV at Stop and Error
Addition
LBA Band
Auxiliary Output 1
Assignment
Character Select
RT
Soak Time Unit
Bank Setting
Level
c
c
c
alsp
rspu
sptr
pidh
pmvd
csca
rsph
rseo
pidi
p-db
pvrp
1300.0
rspl
-200.0
manl
ocu
och
sp-m
ocl
0.50
a-m
off
off
off
off
off
off
M
off
M
M
M
M
M
M
M
M
M
M
M
M
pf
M
M
0.1
M
M
0.0
17
PID Setting
pv
on
Remote SP
Upper Limit
PV Dead Band
Direct Setting of
Position Proportional MV
PV Rate of Change
Calculation Period
Heater Overcurrent
Hysteresis
PF Setting
Level
Remote SP Enable
Remote SP
Lower Limit
PID Set Automatic
Selection Data
PID Set Automatic
Selection Hysteresis
Automatic Cooling
Coefficient Adjustment
Heater Overcurrent
Latch
Alarm SP Selection
SP Tracking
Remote SP Input
Error Output
Manual MV
Limit Enable
Heater Overcurrent
Use
Monitor/Setting
pfd1
pfd3
pfd4
pvdp
d.ref
ra2m
pfd2
pfd5
spdp
ra1m
cmov
pvst
svst
odsl
Item Level
ra1
ra2
rac
0.25
E5@N/E5@N-H
off
off
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
on
M
1
0
0
0
0
0
4
o
0
0
0
0
0
ON/OFF Counter
Reset
Monitor/Setting Item 2
MV Display Selection
SV Status Display
Function
Move to Calibration
Level
Monitor/Setting Item 1
Monitor/Setting Item 3
Monitor/Setting Item 4
Monitor/Setting Item 5
"PV/SP" Display
Screen Selection
PV Decimal Point
Display
PV Status Display
Function
Display Refresh
Period
Control Output 2
ON/OFF Count
Monitor
Control Output 2
ON/OFF Count
Alarm Set Value
Control Output 1
ON/OFF Count
Monitor
Control Output 1
ON/OFF Count
Alarm Set Value
65