AM29DL164DT-120WCI Spansion Inc., AM29DL164DT-120WCI Datasheet - Page 18

no-image

AM29DL164DT-120WCI

Manufacturer Part Number
AM29DL164DT-120WCI
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of AM29DL164DT-120WCI

Cell Type
NOR
Density
16Mb
Access Time (max)
120ns
Interface Type
Parallel
Boot Type
Top
Address Bus
21/20Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
FBGA
Program/erase Volt (typ)
8.5 to 9.5V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
2M/1M
Supply Current
16mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
Sector/Sector Block Protection and
Unprotection
(Note: For the following discussion, the term “sector”
applies to both sectors and sector blocks. A sector
block consists of two or more adjacent sectors that are
protected or unprotected at the same time (see Tables
8 and 9).
Table 8. Top Boot Sector/Sector Block Addresses
18
Sector / Sector
SA12-SA15
SA16-SA19
SA20-SA23
SA24-SA27
SA28-SA30
SA8-SA11
SA1-SA3
SA4-SA7
Block
SA31
SA32
SA33
SA34
SA35
SA36
SA37
SA38
SA0
for Protection/Unprotection
00001XXX,
00010XXX,
001XXXXX
010XXXXX
011XXXXX
100XXXXX
101XXXXX
110XXXXX
11100XXX,
11101XXX,
00000XXX
00011XXX
11110XXX
11111000
11111001
11111010
11111011
11111100
11111101
11111110
11111111
A19–A12
Sector / Sector Block Size
192 (3x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
192 (3x64) Kbytes
64 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
D A T A
Am29DL16xD
S H E E T
The hardware sector protection feature disables both
program and erase operations in any sector. The hard-
ware sector unprotection feature re-enables both
program and erase operations in previously protected
sectors. Sector protection and unprotection can be im-
plemented via two methods.
The primary method requires V
only, and can be implemented either in-system or via
programming equipment. Figure 2 shows the algo-
rithms and Figure 25 shows the timing diagram. This
method uses standard microprocessor bus cycle tim-
ing. For sector unprotect, all unprotected sectors must
first be protected prior to the first sector unprotect
write cycle.
The sector unprotect algorithm unprotects all sectors
in parallel. All previously protected sectors must be in-
dividually re-protected. To change data in protected
sectors efficiently, the temporary sector unprotect
function is available. See “Temporary Sector/Sector
Block Unprotect”.
The alternate method intended only for programming
equipment requires V
This method is compatible with programmer routines
written for earlier 3.0 volt-only AMD flash devices.
Publication number 22243 contains further details;
contact an AMD representative to request a copy.
The device is shipped with all sectors unprotected.
AMD offers the option of programming and protecting
sectors at its factory prior to shipping the device
Sector / Sector
Table 9. Bottom Boot Sector/Sector Block
SA37-SA35
SA34-SA31
SA30-SA27
SA26-SA23
SA22-SA19
SA18-SA15
SA14-SA11
SA10-SA8
Addresses for Protection/Unprotection
Block
SA38
SA7
SA6
SA5
SA4
SA3
SA2
SA1
SA0
11110XXX,
11101XXX,
00001XXX,
00010XXX,
110XXXXX
101XXXXX
100XXXXX
011XXXXX
010XXXXX
001XXXXX
11111XXX
11100XXX
00011XXX
00000111
00000110
00000101
00000100
00000011
00000010
00000001
00000000
A19–A12
ID
on address pin A9 and OE#.
21533E6 February 26, 2009
ID
Sector / Sector Block Size
on the RESET# pin
192 (3x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
256 (4x64) Kbytes
192 (3x64) Kbytes
64 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes
8 Kbytes

Related parts for AM29DL164DT-120WCI