LM90CIMMX National Semiconductor, LM90CIMMX Datasheet - Page 11

no-image

LM90CIMMX

Manufacturer Part Number
LM90CIMMX
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM90CIMMX

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM90CIMMX
Manufacturer:
TAI
Quantity:
40
Part Number:
LM90CIMMX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM90CIMMX
Quantity:
2 100
Company:
Part Number:
LM90CIMMX
Quantity:
4 047
Part Number:
LM90CIMMX/NOPB
Manufacturer:
AMIS
Quantity:
6 246
1.0 Functional Description
1.10 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM90 is transmitting on the SMBData line, the LM90 must be
returned to a known state in the communication protocol.
This may be done in one of two ways:
1. When SMBData is LOW, the LM90 SMBus state ma-
chine resets to the SMBus idle state if either SMBData
or SMBCLK are held low for more than 35ms (t
Note that according to SMBus specification 2.0 all de-
vices are to timeout when either the SMBCLK or SMB-
Data lines are held low for 25-35ms. Therefore, to insure
a timeout of all devices on the bus the SMBCLK or
SMBData lines must be held low for at least 35ms.
(c) Serial Bus Read from a Register with the Internal Command Register preset to desired value.
(a) Serial Bus Write to the internal Command Register followed by a the Data Byte
(b) Serial Bus Write to the Internal Command Register
FIGURE 7. SMBus Timing Diagrams
(Continued)
TIMEOUT
).
11
1.9.1 SMBus Timing Diagrams
2. When SMBData is HIGH, have the master initiate an
1.11 DIGITAL FILTER
In order to suppress erroneous remote temperature readings
due to noise, the LM90 incorporates a user-configured digital
filter. The filter is accessed in the FILTER and ALERT CON-
FIGURE REGISTER at BFh. The filter can be set according
to the following table.
SMBus start. The LM90 will respond properly to an
SMBus start condition at any point during the communi-
cation. After the start the LM90 will expect an SMBus
Address address byte.
20033710
20033711
20033712
www.national.com

Related parts for LM90CIMMX