LM90CIMMX National Semiconductor, LM90CIMMX Datasheet - Page 14

no-image

LM90CIMMX

Manufacturer Part Number
LM90CIMMX
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM90CIMMX

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM90CIMMX
Manufacturer:
TAI
Quantity:
40
Part Number:
LM90CIMMX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM90CIMMX
Quantity:
2 100
Company:
Part Number:
LM90CIMMX
Quantity:
4 047
Part Number:
LM90CIMMX/NOPB
Manufacturer:
AMIS
Quantity:
6 246
www.national.com
2.0 LM90 REGISTERS
2.2 LOCAL and REMOTE TEMPERATURE REGISTERS (LT, RTHB, RTLB)
For LT and RTHB D7–D0: Temperature Data. LSB = 1˚C. Two’s complement format.
For RTLB D7–D5: Temperature Data. LSB = 0.125˚C. Two’s complement format.
The maximum value available from the Local Temperature register is 127; the minimum value available from the Local
Temperature register is -128. The maximum value available from the Remote Temperature register is 127.875; the minimum value
available from the Remote Temperature registers is −128.875.
2.3 STATUS REGISTER (SR)
Power up default is with all bits “0” (zero).
D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm.
D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm.
D2: OPEN: When set to “1” indicates a Remote Diode disconnect.
D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm
D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm.
D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm.
D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm.
D7: Busy: When set to “1” ADC is busy converting.
2.4 CONFIGURATION REGISTER
Power up default is with all bits “0” (zero)
(Read Address 03h /Write Address 09h):
ALERT mask
Read Address
<
P7:P0
B0h-BEh
Command Select Address
D7
BFh
FEh
FFh
13h
14h
19h
20h
21h
>
(Read Only Address 02h):
hex
Busy
D7
RUN/STOP
Write Address
D6
<
P7:P0
B0h-BEh
(Read Only Address 00h, 01h):
(Read Only Address 10h):
LHIGH
BFh
13h
14h
19h
20h
21h
Value
Value
NA
NA
BIT
BIT
D6
>
hex
SIGN
D5
(Continued)
0.5
0
D7
D7
LLOW
<
D5
D7:D0
0000 0000
0000 0000
0101 0101
0101 0101
0000 1010
0000 0000
0000 0001
0010 0001
0.25
D6
D6
64
Power On Default State
>
T_CRIT_A
Remote
binary
RHIGH
mask
0.125
D4
D5
D5
D4
32
14
D4
D4
16
0
<
decimal
RLOW
D7:D0
D3
85
85
10
33
0
0
0
1
D3
0
D3
D3
8
0
>
OPEN
D2
D2
4
0
D2
T_CRIT_A
Register
RHSLB
RLSLB
Name
RDTF
Local
mask
RMID
RCS
RDR
LCS
D2
TH
D1
D1
2
0
RCRIT
D1
D0
D0
1
0
Remote HIGH Setpoint Low
Byte
Remote LOW Setpoint Low
Byte
Remote T_CRIT Setpoint
Local T_CRIT Setpoint
T_CRIT Hysteresis
Manufacturers Test Registers
Remote Diode Temperature
Filter
Read Manufacturer’s ID
Read Stepping or Die Revision
Code
D1
Register Function
0
LCRIT
D0
Fault Queue
D0

Related parts for LM90CIMMX