LM90CIMMX National Semiconductor, LM90CIMMX Datasheet - Page 9

no-image

LM90CIMMX

Manufacturer Part Number
LM90CIMMX
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM90CIMMX

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM90CIMMX
Manufacturer:
TAI
Quantity:
40
Part Number:
LM90CIMMX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM90CIMMX
Quantity:
2 100
Company:
Part Number:
LM90CIMMX
Quantity:
4 047
Part Number:
LM90CIMMX/NOPB
Manufacturer:
AMIS
Quantity:
6 246
1.0 Functional Description
2. Master sends a START followed by the Alert Response
3. Alerting Device(s) send ACK.
4. Alerting Device(s) send their Address. While transmitting
5. Master/slave NoACK
6. Master sends STOP
7. Master attends to conditions that caused the ALERT to
8. Master resets the ALERT mask (D7 in the Configuration
The ARA, 000 1100, is a general call address. No device
should ever be assigned this address.
Bit D0 (the ALERT configure bit) in the FILTER and ALERT
CONFIGURE REGISTER (xBF) must be set low in order for
the LM90 to respond to the ARA command.
The ALERT output can be disabled by setting the ALERT
mask bit, D7, of the Configuration register. The power on
default is to have the ALERT mask bit and the ALERT
configure bit low.
1.3 T_CRIT_A OUTPUT and T_CRIT LIMIT
T_CRIT_A is activated when any temperature reading is
greater than the limit preset in the critical temperature set-
point register (T_CRIT), as shown in Figure 6 . The Status
Register can be read to determine which event caused the
alarm. A bit in the Status Register is set high to indicate
which temperature reading exceeded the T_CRIT setpoint
temperature and caused the alarm, see Section 2.3.
Local and remote temperature diodes are sampled in se-
quence by the A/D converter. The T_CRIT_A output and the
Status Register flags are updated after every Local and
Remote temperature conversion. T_CRT_A follows the state
of the comparison, it is reset when the temperature falls
below the setpoint RCS-TH. The Status Register flags are
reset only after the Status Register is read and if a tempera-
ture conversion(s) is/are below the T_CRIT setpoint, as
shown in . Figure 6
Address (ARA) with a Read Command.
their address, alerting devices sense whether their ad-
dress has been transmitted correctly. (The LM90 will
reset its ALERT output and set the ALERT mask bit once
its complete address has been transmitted successfully.)
be triggered. The STATUS REGISTER is read and fan
started, setpoint limits adjusted, etc.
register).
FIGURE 5. ALERT Output as an SMBus ALERT
Temperature Response Diagram
20033729
(Continued)
9
1.4 POWER ON RESET DEFAULT STATES
LM90 always powers up to these known default states. The
LM90 remains in these states until after the first conversion.
1. Command Register set to 00h
2. Local Temperature set to 0˚C
3. Remote Diode Temperature set to 0˚C until the end of
4. Status Register set to 00h.
5. Configuration register set to 00h; ALERT enabled, Re-
6. 85˚C Local and Remote T_CRIT temperature setpoints
7. 70˚C Local and Remote HIGH temperature setpoints
8. 0˚C Local and Remote LOW temperature setpoints
9. Filter and Alert Configure Register set to 00h; filter dis-
10. Conversion Rate Register set to 8h; conversion rate set
1.5 SMBus INTERFACE
The LM90 operates as a slave on the SMBus, so the
SMBCLK line is an input and the SMBData line is
bi-directional. The LM90 never drives the SMBCLK line and
it does not support clock stretching. According to SMBus
specifications, the LM90 has a 7-bit slave address. All bits A6
through A0 are internally programmed and can not be
changed by software or hardware.
The complete slave address is:
1.6 TEMPERATURE DATA FORMAT
Temperature data can only be read from the Local and
Remote Temperature registers; the setpoint registers
(T_CRIT, LOW, HIGH) are read/write.
Remote temperature data is represented by an 11-bit, two’s
complement word with an LSB (Least Significant Bit) equal
to 0.125˚C. The data format is a left justified 16-bit word
available in two 8-bit registers:
FIGURE 6. T_CRIT_A Temperature Response Diagram
Temperature
A6
the first conversion.
mote T_CRIT alarm enabled and Local T_CRIT alarm
enabled
abled, ALERT output set as an SMBus ALERT
to 16 conv./sec.
1
+125˚C
A5
0
A4
0
0111 1101 0000 0000
Binary
A3
1
Digital Output
A2
1
A1
0
www.national.com
7D00h
Hex
20033706
A0
0