SC16C2550IB48,157 NXP Semiconductors, SC16C2550IB48,157 Datasheet - Page 12

no-image

SC16C2550IB48,157

Manufacturer Part Number
SC16C2550IB48,157
Description
IC DUART SOT313-2
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C2550IB48,157

Features
2 Channels
Number Of Channels
2, DUART
Fifo's
16 Byte
Voltage - Supply
3.5 V ~ 4.5 V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935270020157
SC16C2550IB48
SC16C2550IB48
Philips Semiconductors
9397 750 11621
Product data
6.6 Special feature software flow control
6.7 Hardware/software and time-out interrupts
the SC16C2550 compares two consecutive receive characters with two software flow
control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions
accordingly. Under the above described flow control mechanisms, flow control
characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed,
the SC16C2550 automatically sends an Xoff message (when enabled) via the serial
TX output to the remote modem. The SC16C2550 sends the Xoff1,2 characters as
soon as received data passes the programmed trigger level. To clear this condition,
the SC16C2550 will transmit the programmed Xon1,2 characters as soon as receive
data drops below the programmed trigger level.
A special feature is provided to detect an 8-bit character when EFR[5] is set. When
8-bit character is detected, it will be placed on the user-accessible data stack along
with normal incoming RX data. This condition is selected in conjunction with
EFR[0-3]. Note that software flow control should be turned off when using this special
mode by setting EFR[0-3] to a logic 0.
The SC16C2550 compares each incoming receive character with Xoff2 data. If a
match exists, the received data will be transferred to the FIFO, and ISR[4] will be set
to indicate detection of a special character. Although the Internal Register Table
(Table
number of bits is dependent on the programmed word length. Line Control Register
bits LCR[0-1] define the number of character bits, i.e., either 5 bits, 6 bits, 7 bits or
8 bits. The word length selected by LCR[0-1] also determine the number of bits that
will be used for the special character comparison. Bit 0 in the X-registers corresponds
with the LSB bit for the receive character.
The interrupts are enabled by IER[0-3]. Care must be taken when handling these
interrupts. Following a reset, if Interrupt Enable Register (IER) bit 1 = 1, the
SC16C2550 will issue a Transmit Holding Register interrupt. This interrupt must be
serviced prior to continuing operations. The LSR register provides the current
singular highest priority interrupt only. It could be noted that CTS and RTS interrupts
have lowest interrupt priority. A condition can exist where a higher priority interrupt
may mask the lower priority CTS/RTS interrupt(s). Only after servicing the higher
pending interrupt will the lower priority CTS/RTS interrupt(s) be reflected in the status
register. Servicing the interrupt without investigating further interrupt conditions can
result in data errors.
When two interrupt conditions have the same priority, it is important to service these
interrupts correctly. Receive Data Ready and Receive Time Out have the same
interrupt priority (when enabled by IER[3]). The receiver issues an interrupt after the
number of characters have reached the programmed trigger level. In this case, the
SC16C2550 FIFO may hold more characters than the programmed trigger level.
Following the removal of a data byte, the user should re-check LSR[0] for additional
characters. A Receive Time Out will not occur if the receive FIFO is empty. The
time-out counter is reset at the center of each stop bit received or each time the
7) shows each X-Register with eight bits of character information, the actual
Dual UART with 16 bytes of transmit and receive FIFOs and IrDA
Rev. 03 — 19 June 2003
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
SC16C2550
encoder/decoder
12 of 46