SST89V58RD Silicon Storage Technology, SST89V58RD Datasheet - Page 32

no-image

SST89V58RD

Manufacturer Part Number
SST89V58RD
Description
FlashFlex51 MCU
Manufacturer
Silicon Storage Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SST89V58RD2-33-C-NJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-C-NJE
Manufacturer:
SST
Quantity:
20 000
Part Number:
SST89V58RD2-33-C-TQJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-I-N
Manufacturer:
SST
Quantity:
134
Part Number:
SST89V58RD2-33-I-NJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-I-TQJE
Manufacturer:
Microchip Technology
Quantity:
10 000
www.DataSheet4U.com
Data Sheet
Timer/Counter 2 Control Register (T2CON)
Timer/Counter 2 Mode Control (T2MOD)
©2006 Silicon Storage Technology, Inc.
Location
Location
C8H
C9H
Symbol
TF2
EXF2
RCLK
TCLK
EXEN2
TR2
C/T2#
CP/RL2#
Symbol
X
-
T2OE
DCEN
TF2
7
7
X
EXF2
6
Function
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2
will not be set when either RCLK or TCLK = 1.
Timer 2 external flag set when either a capture or reload is caused by a negative
transition on T2EX and EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will
cause the CPU to vector to the Timer 2 interrupt routine. EXF2 must be cleared by
software. EXF2 does not cause an interrupt in up/down counter mode (DCEN = 1).
Receive clock flag. When set, causes the serial port to use Timer 2 overflow pulses for
its receive clock in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for
the receive clock.
Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for
its transmit clock in modes 1 and 3. TCLK = 0 causes Timer 1 overflow to be used for
the transmit clock.
Timer 2 external enable flag. When set, allows a capture or reload to occur as a result
of a negative transition on T2EX if Timer 2 is not being used to clock the serial port.
EXEN2 = 0 causes Timer 2 to ignore events at T2EX.
Start/stop control for Timer 2. A logic 1 starts the timer.
Timer or counter select (Timer 2)
0: Internal timer (OSC/6 in 6 clock mode, OSC/12 in 12 clock mode)
1: External event counter (falling edge triggered)
Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if
EXEN2 = 1. When cleared, auto-reloads will occur either with Timer 2 overflows or
negative transitions at T2EX when EXEN2 = 1. When either RCLK = 1 or TCLK = 1,
this bit is ignored and the timer is forced to auto-reload on Timer 2 overflow.
6
Function
Don’t Care
Not implemented, reserved for future use.
Note: User should not write ‘1’s to reserved bits. The value read from a reserved bit is indeterminate.
Timer 2 Output Enable bit.
Down Count Enable bit. When set, this allows Timer 2 to be configured as an up/down
counter.
-
SST89E52RD2/RD / SST89E54RD2/RD / SST89E58RD2/RD
SST89V52RD2/RD / SST89V54RD2/RD / SST89V58RD2/RD
RCLK
5
5
-
TCLK
4
4
-
32
EXEN2
3
3
-
TR2
2
2
-
C/T2#
T2OE
1
1
FlashFlex51 MCU
CP/RL2#
DCEN
0
0
S71255-05-000
Reset Value
Reset Value
xxxxxx00b
00H
5/06

Related parts for SST89V58RD