SST89V58RD Silicon Storage Technology, SST89V58RD Datasheet - Page 45

no-image

SST89V58RD

Manufacturer Part Number
SST89V58RD
Description
FlashFlex51 MCU
Manufacturer
Silicon Storage Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SST89V58RD2-33-C-NJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-C-NJE
Manufacturer:
SST
Quantity:
20 000
Part Number:
SST89V58RD2-33-C-TQJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-I-N
Manufacturer:
SST
Quantity:
134
Part Number:
SST89V58RD2-33-I-NJE
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
SST89V58RD2-33-I-TQJE
Manufacturer:
Microchip Technology
Quantity:
10 000
www.DataSheet4U.com
FlashFlex51 MCU
SST89E52RD2/RD / SST89E54RD2/RD / SST89E58RD2/RD
SST89V52RD2/RD / SST89V54RD2/RD / SST89V58RD2/RD
7.0 WATCHDOG TIMER
The device offers a programmable Watchdog Timer (WDT)
for fail safe protection against software deadlock and auto-
matic recovery.
To protect the system against software deadlock, the user
software must refresh the WDT within a user-defined time
period. If the software fails to do this periodical refresh, an
internal hardware reset will be initiated if enabled (WDRE=
1). The software can be designed such that the WDT times
out if the program does not work properly.
The WDT in the device uses the system clock (XTAL1) as
its time base. So strictly speaking, it is a watchdog counter
rather than a watchdog timer. The WDT register will incre-
ment every 344,064 crystal clocks. The upper 8-bits of the
time base register (WDTD) are used as the reload register
of the WDT.
©2006 Silicon Storage Technology, Inc.
FIGURE
Ext. RST
CLK (XTAL1)
7-1: Block Diagram of Programmable Watchdog Timer
WDTC
Counter
344064
clks
WDT Upper Byte
45
WDTD
The WDTS flag bit is set by WDT overflow and is not
changed by WDT reset. User software can clear WDTS by
writing “1” to it.
Figure 7-1 provides a block diagram of the WDT. Two SFRs
(WDTC and WDTD) control watchdog timer operation.
During idle mode, WDT operation is temporarily sus-
pended, and resumes upon an interrupt exit from idle.
The time-out period of the WDT is calculated as follows:
where WDTD is the value loaded into the WDTD register
and f
OSC
Period = (255 - WDTD) * 344064 * 1/f
is the oscillator frequency.
WDT Reset
1255 F22.0
Internal Reset
S71255-05-000
CLK (XTAL1)
Data Sheet
5/06

Related parts for SST89V58RD