30LVS Vishay Siliconix, 30LVS Datasheet

no-image

30LVS

Manufacturer Part Number
30LVS
Description
AC Line Rated Disc Capacitors
Manufacturer
Vishay Siliconix
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
30LVS10-R
Manufacturer:
VSC
Quantity:
1 599
Company:
Part Number:
30LVSD27-R
Quantity:
70 000
Part Number:
30LVSD68-R
Manufacturer:
VISHAY/威世
Quantity:
20 000
Company:
Part Number:
30LVSD68-R
Quantity:
70 000
Part Number:
30LVSS10-R
Manufacturer:
VISHAY/威世
Quantity:
20 000
www.DataSheet4U.com
440L, 30LV, 30LVS, 25Y, 125L, 20VL Series
Vishay Cera-Mite
X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE,
LINE-BY-PASS, ANTENNA COUPLING
Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specifi cally designed and tested
for use on 125 Volt through 600 Volt AC power sources. Certifi ed to meet demanding X & Y type worldwide
safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass
fi ltering applications. Vishay Cera-Mite offers the most
complete selection in the industry—six product families—
exactly tailored to your needs.
Note 1
Voltage Ratings: All ratings are manufacturer’s
rating.
• Part markings are governed by agency
• Parts are marked 250 VAC unless otherwise
Note 2
UL1414 Across-The-Line, Antenna Coupling, and
Line-By-Pass Capacitors:
• Across-The-Line—A capacitor connected
• Antenna-Coupling—A capacitor connected
• Line-By-Pass—A capacitor connected between
www.vishay.com
20
Series / Recognition / Voltage
Underwriters Laboratories Inc.: (Note 2)
Electromagnetic Interference Filters
Canadian Standards Association:
European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:
IEC 384 -14 Second Edition Subclass Y: (Note 3)
IEC 384-14 Second Edition Subclass X: (Note 4)
Damp Heat, Steady State Recognition
SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS
Worldwide Safety Agency Recognition
- Underwriters Laboratories - UL1414 & UL1283
- Canadian Standards Association - CSA 22.2 No. 1 & No. 8
- European EN132400 to IEC 384-14 Second Edition
Required In AC Power Supply and Filter Applications
Six Families Tailored To Specific Industry Requirements
Complete Range of Capacitance Values
one side of a supply circuit and an accessible
conductive part.
rules and customer requirements.
requested.
either across a supply circuit or between
one side of a supply circuit and a conductive
part that may be connected to earth ground.
from an antenna terminal to circuits within an
appliance.
CSA 22.2 No.1 Across-The-Line
Type of Insulation Bridged
UL 1414 Across-The-Line
UL 1414 Antenna Coupling
UL 1414 Line-By-Pass
UL 1414 Rated Voltage
UL1283 Rated Voltage
CSA 22.2 No.1 Isolation
CSA 22.2 No. 1 Rated Voltage
CSA 22.2 No. 8 Line-to-Ground Capacitors
Subclass Y Voltage (Vrms 50-60 Hz)
Peak Impulse Voltage Before Endurance Test
Subclass X Voltage (Vrms 50-60 Hz)
Peak Impulse Voltage in Service
Application
CSA 22.2 No. 8 Rated Voltage
For Use in Certified EMI Filters
AC Line Rated Disc Capacitors
Antenna-Coupling Antenna-Coupling
Across-The-Line Across-The-Line
Across-The-Line Across-The-Line
Line-By-Pass
2.5 to 4.0 kV
Note 3
IEC 384-14 Subclass Y Capacitors:
• A capacitor of a type suitable for use in situations
• Class Y capacitors are divided into sub- classes
• For definitions of basic, supplementary,
• Subclass Y capacitors may be used in
Note 4
IEC 384-14 Subclass X Capacitors:
• A capacitor of a type suitable for use
EMI Filters
Reinforced
High Pulse
Double or
250 VAC
600 VAC
250 VAC
500 VAC
400 VAC
Isolation
where failure of the capacitor could lead to
danger of electric shock.
based on type of insulation bridged and voltage
ranges.
double and reinforced insulation, see IEC
Publication 536.
applications which require a Subclass
X rating.
in situations where failure of the capacitor
would not lead to danger of electric
shock.
440L
8 kV
Y1
X1
ceramite.support@vishay.com
Certified EMI Filters Certified EMI Filters Certified EMI Filters
Line-To-Ground
Supplementary
Line-By-Pass
2.5 to 4.0 kV
EMI Filters
High Pulse
250 VAC
250 VAC
250 VAC
400 VAC
300 VAC
400 VAC
Isolation
Basic or
30LV
5 kV
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS
PERFORMANCE DATA / SERIES: 440L
Application Voltage Range
(Vrms 50/60 Hz) (Note 1)
Dielectric Strength
(Vrms 50/60 H
Dissipation Factor (Maximum)
Insulation Resistance (Minimum)
Mechanical Data
Temperature Characteristics
Y2
X1
Code HKF - 25°C/ + 125°C/21 days
Line-To-Ground
Supplementary
Line-By-Pass
2.5 to 4.0 kV
Z
EMI Filters
High Pulse
250 VAC
250 VAC
250 VAC
400 VAC
250 VAC
400 VAC
Isolation
Basic or
for 1 minute)
30LVS
5 kV
Y2
X1
Line-To-Ground
Supplementary
Line-By-Pass
2.5 to 4.0 kV
• Class X capacitors are divided into subclasses
Note 5
AC Leakage Current:
• For all Series (except 125L) - AC Leakage
• For 125L Series - AC Leakage Current
Note 6
Alternate Lead Spacings of 7.5mm and 10mm
are available bulk or tape & reel.
• European Required Minimum Lead Clearance
High Pulse
EMI Filters
250 VAC
250 VAC
250 VAC
400 VAC
250 VAC
400 VAC
Isolation
Basic or
according to the peak impulse test voltage
superimposed on the main voltage
Current (mA) specifi ed at 250 Vrms, 60 Hz.
(mA) specifi ed at 125 Vrms, 60Hz.
(Prevents Use of Inside Crimp) .315" (8mm) on
440L Series; 0.118" (3mm) on all other series.
250/500 300/400 250/400 250/400
25Y
5 kV
4000
See Part Number Detail for Temperature Characteristics
Y5U
Y2
X1
Service Temperature 125°C Maximum;
Coating Material per UL94V0
30LV 30LVS
2500 2500
Y5U
Supplementary
Line-By-Pass
125/250 VAC
2.5 to 4.0 kV
High Pulse
1000 F
Document Number: 23092
250 VAC
125 VAC
400 VAC
Isolation
Basic or
2.5 kV
Y5U
125L
2%
Y4
X1
Revision 14-May-02
2500 2000 1250
Y5S
25Y
Certified EMI Filters
Line-To-Ground
Gen. Purpose
EMI Filters
125L 20VL
To 2.5 kV
250 VAC
250 VAC
400 VAC
Y5V Y5V
250
20VL
X2
250

Related parts for 30LVS

30LVS Summary of contents

Page 1

... Series Vishay Cera-Mite X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE, LINE-BY-PASS, ANTENNA COUPLING Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specifi cally designed and tested for use on 125 Volt through 600 Volt AC power sources. Certifi meet demanding X & Y type worldwide safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass fi ...

Page 2

... Y5U .680 (17.3) .195 (5.0) .375 (9.5) 20 .032 (.81) 30LVD90 1.37 Y5U .720 (18.3) .200 (5.1) .375 (9.5) 20 .032 (.81) 30LVS10 1.52 Y5U .790 (20.1) .190 (4.8) .375 (9.5) 20 .032 (.81) 2.28 Y5U .900 (22.9) .200 (5.1) .375 (9.5) 20 .032 (.81) Note 5 Note 6 * 30LVS15 not available with UL 1414 recognition max G b 4mm max T 1.250" min (32) "LO" typ. ...

Page 3

... Series 440L, 30LV, 30LVS, 25Y, 125L, 20VL Series Vishay Cera-Mite INTERNATIONAL SAFETY AGENCY APPROVALS Agency Files/ Licenses Underwriters Laboratories Inc. UL 1414 Antenna-Coupling Components UL 1414 Line-By-Pass Components UL 1283 Electromagnetic Interference Filters Canadian Standards Association: CSA 22.2 No.1 Across-The-Line, Isolation CSA 22 ...

Related keywords