MV1820 Mitel Networks Corporation, MV1820 Datasheet - Page 3

no-image

MV1820

Manufacturer Part Number
MV1820
Description
Video Programme Delivery Control Interface Circuit
Manufacturer
Mitel Networks Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MV1820FCG
Manufacturer:
GPS
Quantity:
20 000
MV1820
CRYSTAL SPECIFICATION
FUNCTIONAL DESCRIPTION
synchronising signals. Timing circuits monitor the sync signal
to enable the MV1820 to lock onto the broadcast signal. A
timing window, for the Vertical Blanking Interval (VBI) lines 6
- 22 and 318 - 335, is established to enable the acquisition
circuit to monitor the sliced data signal for valid teletext data.
Teletext (WST) data. Magazine, packet and designation code
bytes are checked and valid Broadcast Service Data Packets
(BSDP) format two type only are accepted. These are known
as packet 8/30. Format two is signalled by byte six, data bit two
being set high and bits 3 and 4 set low. Bytes 13 to 25 inclusive
are Hamming decoded (8,4) and stored in seven registers
each of eight bits. If the complete message is correctly
received with no uncorrectable Hamming errors, an interrupt
to the microprocessor is signalled by the DAV (bar) pin going
low. At the same time the data is transferred to a second bank
of registers, reorganised with original numbered bytes 14, 15,
24, 25 and 13 placed after byte 23, to be read out on the I
bus when so requested. Subsequent valid messages will
continue to be transferred to the output registers overwriting
any existing data. In this way the output registers always
contain the latest PDC message.
with a selectable address. The I
(20 + 1 hex) with the address select (AS) pin set high, or 0010
0011 (22 + 1 hex) with the AS pin set low. The read bit (LSB)
must always be set, it is not possible to write to the MV1820.
acknowledge and then transmit on the SDA line the first byte
from the output registers (decoded byte 16 and 17) most
4
Parallel resonant fundamental frequency 27.750000MHz. AT cut.
Tolerance at -10°C to 60°C ± 50ppm.
Tolerance overall ± 100ppm.
The video signal is sliced to produce data and
The framing code is checked for valid World System
The MV1820 is configured as an I
On recognising its address, the MV1820 will send an
2
C bus address is 0010 0001
2
C bus slave transmitter
Fig.3 Typical application diagram
2
C
significant bit (MSB) first. It will then monitor the SDA line for
an acknowledge from the microprocessor. If the
microprocessor does NOT send an acknowledge, the
MV1820 will release the data line to allow the microprocessor
to send a stop condition. If the microprocessor does send an
acknowledge, the following bytes of the message will be
output provided each byte is acknowledged. The final data will
be byte 13 followed by the four ‘1’s.
and the output registers are all set high. If the microprocessor
continues to send clocks on the SCL line, the MV1820 will
output FF bytes on the SDA line. Also, if the MV1820 is re-
addressed before another PDC message is received, the
MV1820 will output FF bytes on the SDA line. The
microprocessor can prematurely stop the message by NOT
sending an Acknowledge followed by a STOP condition after
any byte has been sent by the MV1820. The registers will then
be reset to FF bytes and the DAV pin will be reset high.
registers during I
in the incoming registers until I
they may be overwritten by new PDC messages until the I
bus activity ceases and they can then be transferred to the
output registers.
oscillator together with an external parallel resonant
fundamental frequency AT cut crystal.
registers will contain FF bytes and the DAV pin will be set high.
When the power supply is removed, the I
clamped to ground, leaving it free for other I
When readout is complete, the DAV (bar) pin is reset high
To prevent any corruption of the data in the output
System clock is provided by an on - chip 27.75MHz
Following a reset, RESET pulled low, the output I
Nominal load capacitance 20pF.
Equivalent series resistance <20Ω.
2
C bus activity, valid PDC messages are held
2
C bus activity ceases. Here
2
C bus will not be
2
C bus traffic.
2
C bus
2
C