s908qc16g0cdte Freescale Semiconductor, Inc, s908qc16g0cdte Datasheet - Page 124

no-image

s908qc16g0cdte

Manufacturer Part Number
s908qc16g0cdte
Description
M68hc08 Family Of 8-bit Microcontroller Units Mcus
Manufacturer
Freescale Semiconductor, Inc
Datasheet
Timer Interface Module (TIM)
14.3.4.3 PWM Initialization
To ensure correct operation when generating unbuffered or buffered PWM signals, use the following
initialization procedure:
Setting MS0B links channels 0 and 1 and configures them for buffered PWM operation. The TIM
channel 0 registers (TCH0H:TCH0L) initially control the buffered PWM output. TIM status control
register 0 (TSCR0) controls and monitors the PWM signal from the linked channels. MS0B takes priority
over MS0A.
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on TIM overflows. Subsequent output
compares try to force the output to a state it is already in and have no effect. The result is a 0% duty cycle
output.
Setting the channel x maximum duty cycle bit (CHxMAX) and setting the TOVx bit generates a 100% duty
cycle output. See
124
1. In the TIM status and control register (TSC):
2. In the TIM counter modulo registers (TMODH:TMODL), write the value for the required PWM
3. In the TIM channel x registers (TCHxH:TCHxL), write the value for the required pulse width.
4. In TIM channel x status and control register (TSCx):
5. In the TIM status control register (TSC), clear the TIM stop bit, TSTOP.
period.
a. Stop the counter by setting the TIM stop bit, TSTOP.
b. Reset the counter and prescaler by setting the TIM reset bit, TRST.
a. Write 0:1 (for unbuffered output compare or PWM signals) or 1:0 (for buffered output compare
b. Write 1 to the toggle-on-overflow bit, TOVx.
c. Write 1:0 (polarity 1 — to clear output on compare) or 1:1 (polarity 0 — to set output on
or PWM signals) to the mode select bits, MSxB:MSxA. See
compare) to the edge/level select bits, ELSxB:ELSxA. The output action on compare must
force the output to the complement of the pulse width level. See
channel. Writing to the active channel registers is the same as generating
unbuffered PWM signals.
In PWM signal generation, do not program the PWM channel to toggle on
output compare. Toggling on output compare prevents reliable 0% duty
cycle generation and removes the ability of the channel to self-correct in the
event of software error or noise. Toggling on output compare can also
cause incorrect PWM signal generation when changing the PWM pulse
width to a new, much larger value.
14.8.1 TIM Status and Control
MC68HC08QY/QT Family Data Sheet, Rev. 2
NOTE
Register.
Table
Table
14-2.
14-2.
Freescale Semiconductor

Related parts for s908qc16g0cdte