10.1.4
If the reset pin RO is pulled to low from outside while no reset low is issued by the SBC, the device goes to Restart
Mode. In Restart Mode an reset is issued by the SBC, the RO pin is set to low for the time
pin is pulled to low for longer time Reset clamped is detected.
10.2
Two different Watchdogs are possible in the SBC. It can be either a Window Watchdog or a Time-out Watchdog.
The Watchdog can also be inhibited in SBC Stop Mode and SBC SW Flash Mode via SPI. The Watchdog timing
is programmed via SPI command. As soon as the Watchdog is activated, the timer starts running and the
Watchdog must be served. Please refer to
The default setting for the Watchdog is Time-out Watchdog with a 256 ms timer. The long open window allows the
microcontroller to run its initialization sequences and then to trigger the Watchdog via the SPI.
The Watchdog is served by a SPI bit and should toggle with the correct frequency. The default value is a 0, so the
first trigger bit must be a 1.
In case of a Watchdog reset, the Watchdog immediately starts with a long open window when entering SBC
Normal Mode. With the reset the watchdog bit is set to 0, so the first watchdog trigger after reset is a change to 1.
In SBC Software Development Mode, no reset is generated due to watchdog failure, if a watchdog failure occurs
it is indicated by the SPI Reset bit and via INT pin. All watchdog modes are accessible in regards to the normal
operation modes.
Table 8
SBC Mode
INIT Mode
Normal Mode
Software Flash Mode
Stop Mode
Sleep Mode
Fail-Safe Mode
Restart Mode
Data Sheet
Reset from Outside
Watchdog
Watchdog Functionality by SBC Modes
Watchdog Mode
Watchdog Programmable;
Watchdog is not active.
WD Programmable;
Time-out or Window Watchdog
Mode is fixed
Mode is fixed
OFF
OFF
OFF
Table 8
to match the SBC Modes with the Watchdog Modes.
44
Remarks
INIT Mode should be left in less than 256 ms (see
Chapter
SBC retains the set-up as in the mode before entering
the Software Flash Mode
SBC retains the set up as in the mode before entering
the Stop Mode
SBC does not retain the set-up.
SBC does not retain the set-up
SBC will start default Watchdog setting (256ms
Time-out Watchdog) when entering Normal Mode.
12)
Supervision Functions
t
Rev. 1.0, 2009-05-26
RD1
or
TLE8261-2E
t
RD2
. If the RO