regulator output or an over-voltage on the PWM output
disables all converters and drives the FAULT pin to VCC.
Figure 7 shows a simplified schematic of the fault logic. An
over-voltage detected on VSEN1 immediately sets the fault
latch. A sequence of three over-current fault signals also
sets the fault latch. A comparator indicates when C
charged (UP signal), such that an under-voltage event on
either linear output (FB2 or FB3) is ignored until after the
soft-start interval (T4 in Figure 6). At startup, this allows
V
without generating a fault. Cycling the bias input voltage
(+12V
the fault latch.
Over-Voltage Protection
During operation, a short on the upper PWM MOSFET (Q1)
causes V
over-voltage threshold of 115% (typical) of DACOUT, the
over-voltage comparator trips to set the fault latch and turns
Q2 on as required in order to regulate V
DACOUT. This blows the input fuse and reduces V
The fault latch raises the FAULT pin close to VCC potential.
A separate over-voltage circuit provides protection during
the initial application of power. For voltages on the VCC pin
below the power-on reset (and above ~4V), V
monitored for voltages exceeding 1.26V. Should VSEN1
exceed this level, the lower MOSFET (Q2) is driven on as
needed to regulate V
Over-Current Protection
All outputs are protected against excessive over-currents.
The PWM controller uses the upper MOSFET’s on-
resistance, r
against shorted outputs. The linear regulator monitors the
current of the integrated power device and signals an over-
current condition for currents in excess of 230mA.
Additionally, both the linear regulator and the linear
controller monitor FB2 and FB3 for under-voltage to protect
against excessive currents.
LUV
OC1
SS
OV
OUT2
0.15V
FIGURE 7. FAULT LOGIC - SIMPLIFIED SCHEMATIC
4V
IN
and V
on the VCC pin) off then on resets the counter and
OUT1
+
-
+
-
DS(ON)
OUT3
to increase. When the output exceeds the
CURRENT
UP
LATCH
OVER
S
R
to slew up over increased time intervals,
to monitor the current for protection
OUT1
Q
POR
to 1.26V.
231
R
COUNTER
S
OUT1
INHIBIT
LATCH
FAULT
S
R
OUT1
to 1.15 x
Q
SS
OUT1
is
VCC
is fully
FAULT
.
HIP6018
Figures 8 and 9 illustrate the over-current protection with an
overload on OUT1. The overload is applied at T0 and the
current increases through the output inductor (L
T1, the OVER-CURRENT1 comparator trips when the voltage
across Q1 (I
R
capacitor (C
counter. C
with the error amplifiers clamped by soft-start. With OUT1 still
overloaded, the inductor current increases to trip the over-
current comparator. Again, this inhibits all outputs, but the
soft-start voltage continues increasing to 4V before
discharging. The counter increments to 2. The soft-start cycle
repeats at T3 and trips the over-current comparator. The SS
pin voltage increases to 4V at T4 and the counter increments to
3. This sets the fault latch to disable the converter. The fault is
reported on the FAULT pin.
The linear regulator operates in the same way as PWM1 to
over-current faults. Additionally, the linear regulator and
linear controller monitor the feedback pins for an under-
voltage. Should excessive currents cause FB2 or FB3 to fall
below the linear under-voltage threshold, the LUV signal
sets the over-current latch if C
LUV signal during the C
outputs to build above the under-voltage threshold during
normal start-up. Cycling the bias input power off then on
resets the counter and the fault latch.
Resistor R
PWM converter. As shown in Figure 9, the internal 200µA
current sink develops a voltage across R
referenced to V
comparator (OVER-CURRENT1). When the voltage across the
upper MOSFET (V
comparator trips to set the over-current latch. Both V
V
R
DS
OCSET
OCSET
10V
0A
0V
4V
2V
0V
are referenced to V
. This inhibits all outputs, discharges the soft-start
helps V
SS
OCSET1
FIGURE 8. OVER-CURRENT OPERATION
T0
D
COUNT
SS
recharges at T2 and initiates a soft-start cycle
= 1
T1
) with a 11µA current sink, and increments the
OVERLOAD
APPLIED
IN
r
DS(ON)
OCSET
. The DRIVE signal enables the over-current
DS(ON)
programs the over-current trip level for the
SS
) exceeds the level programmed by
IN
track the variations of V
T2
) exceeds V
and a small capacitor across
charge interval allows the linear
COUNT
SS
TIME
= 2
REPORTED
is fully charged. Blanking the
FAULT
SET
OCSET
, the over-current
T3
OUT1
IN
(V
COUNT
SET
due to
= 3
T4
SET
). At time
) that is
and