xr16v2651im Exar Corporation, xr16v2651im Datasheet - Page 5

no-image

xr16v2651im

Manufacturer Part Number
xr16v2651im
Description
High Performance Duart With 32-byte Fifo And Powersave
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16v2651im-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Pin Description
REV. 1.0.2
ANCILLARY SIGNALS
PwrSave
OP2A#
CTSB#
DTRB#
DSRB#
OP2B#
RTSB#
XTAL1
XTAL2
CDB#
N
RIB#
RXB
TXB
AME
32-QFN
P
15
16
10
11
IN
6
3
9
-
-
-
-
-
-
#
48-TQFP
P
HIGH PERFORMANCE DUART WITH 32-BYTE FIFO AND POWERSAVE FEATURE
32
22
23
35
20
16
21
13
14
12
IN
8
4
9
#
T
YPE
O
O
O
O
O
O
I
I
I
I
I
I
I
Output Port 2 Channel A - The output state is defined by the user and through the
software setting of MCR[3]. INTA is set to the active mode and OP2A# output LOW
when MCR[3] is set to a logic 1. INTA is set to the three state mode and OP2A#
output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTA is used, this out-
put should not be used as a general output else it will disturb the INTA output func-
tionality.
UART channel B Transmit Data or infrared encoder data. Standard transmit and
receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be
HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is
enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the
Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected.
UART channel B Receive Data or infrared receive data. Normal receive data input
must idle HIGH. The infrared receiver pulses typically idles at logic 0 but can be
inverted by software control prior going in to the decoder, see MCR[6]. If this pin is
not used, tie it to VCC or pull it high via a 100k ohm resistor.
UART channel B Request-to-Send (active low) or general purpose output. This port
must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1], and
IER[6].
UART channel B Clear-to-Send (active low) or general purpose input. It can be
used for auto CTS flow control, see EFR[7], and IER[7]. This input should be con-
nected to VCC when not used.
UART channel B Data-Terminal-Ready (active low) or general purpose output. If it
is not used, leave it unconnected.
UART channel B Data-Set-Ready (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
UART channel B Carrier-Detect (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
UART channel B Ring-Indicator (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
Output Port 2 Channel B - The output state is defined by the user and through the
software setting of MCR[3]. INTB is set to the active mode and OP2B# output LOW
when MCR[3] is set to a logic 1. INTB is set to the three state mode and OP2B#
output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTB is used, this out-
put should not be used as a general output else it will disturb the INTB output func-
tionality.
Crystal or external clock input.
Crystal or buffered clock output.
PowerSave (active high). This feature isolates the V2651’s data bus interface from
the host preventing other bus activities that cause higher power drain during sleep
mode. See Sleep Mode with Auto Wake-up and PowerSave Feature section for
details.
5
D
ESCRIPTION
XR16V2651

Related parts for xr16v2651im