ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 8.
Parameter
Storage Temperature
Operating Temperature
Supply Voltage Ranges
Input Voltage Range
Output Voltage Range
Average Output Current,
Common-Mode Transients
1
2
3
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Refers to common-mode transients across the insulation barrier. Common-
All voltages are relative to their respective ground.
V
given channel, respectively.
See Figure 2 for information on maximum allowable current for various
temperatures.
mode transients exceeding the Absolute Maximum Rating can cause
latch-up or permanent damage.
DDI
per Pin
and V
3
DDO
refer to the supply voltages on the input and output sides of a
1, 2
1, 2
1
4
Symbol
T
T
V
V
V
V
I
CM
O
ST
A
DD1
DD2
IA
OA
, V
, V
H
, CM
IB
OB
L
Rating
−55°C to +150°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to +27 V
−0.5 V to V
−0.5 to V
−23 mA to +23 mA
−100 kV/μs to +100 kV/μs
DDO
DDI
+ 0.5
+ 0.5
Rev. 0 | Page 7 of 16
Table 9. Maximum Continuous Working Voltage
Parameter
AC Bipolar Voltage
AC Unipolar Voltage
DC Voltage
1
barrier. See the Insulation Lifetime section for more details.
2
3
4
ESD CAUTION
Refers to continuous voltage magnitude imposed across the isolation
See Figure 21.
See Figure 22.
See Figure 23.
Functional Insulation
Basic Insulation
Functional Insulation
Basic Insulation
4
2
3
Max
565
1131
560
1131
560
Unit
V peak
V peak
V peak
V peak
V peak
Constraint
50-year minimum lifetime
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1 and VDE V
0884-10
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1 and
VDE V 0884-10
ADuM3220