HD6432646 Hitachi, HD6432646 Datasheet - Page 461

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
12.3.2
To use the WDT as an interval timer, clear the WT/IT bit in TCSR to 0 and set the TME bit to 1.
An interval timer interrupt (WOVI) is generated each time TCNT overflows, provided that the
WDT is operating as an interval timer, as shown in figure 12-5. This function can be used to
generate interrupt requests at regular intervals.
12.3.3
The OVF flag is set to 1 if TCNT overflows during interval timer operation. At the same time, an
interval timer interrupt (WOVI) is requested. This timing is shown in figure 12-6.
With WDT1, the OVF bit of the TCSR is set to 1 and a simultaneous NMI interrupt is requested
when the TCNT overflows if the NMI request has been chosen in the watchdog timer mode.
Legend
WOVI: Interval timer interrupt request generation
H'FF
H'00
TCNT value
WT/IT=0
TME=1
Interval Timer Operation
Timing of Setting Overflow Flag (OVF)
Overflow
WOVI
Figure 12-5 Interval Timer Operation
Overflow
WOVI
Overflow
WOVI
Overflow
WOVI
Time
427