WIZ120SR-EVB WIZnet, WIZ120SR-EVB Datasheet - Page 15

no-image

WIZ120SR-EVB

Manufacturer Part Number
WIZ120SR-EVB
Description
Interface Development Tools EVALUATION BOARD FOR WIZ120SR
Manufacturer
WIZnet
Type
Serial to Ethernetr
Datasheet

Specifications of WIZ120SR-EVB

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
WIZ120SR
Interface Type
Ethernet, RS-232
Operating Supply Voltage
5 V
Dimensions
110 mm x 60 mm
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Operating Supply Current
200 mA
2.2.2. Port Setting
Figure 4. Configuration Tool (Serial Configuration)
You should set to UART configuration after checking UART tab whether it is UART0 or UART1.
The numbers on the screenshot correspond to the descriptions listed below.
① Serial
This menu is used for setting up your serial configurations.
☞ In order to apply your settings, click the “Setting” button
② Inactivity time
When there is no data transmission, the connection will close automatically after the time
specified in the Inactivity time.
If the default value ‘0‟ is set as the Inactivity time, the network connection is maintained
even though there is no data transmission. In order to close the connection, you should use
the „Close‟ commands.
This function is useful when you have two or more systems which are connected to the
WZ120SR module. When one system is connected to the WIZ120SR, other systems cannot
connect to the module simultaneously. If you defined a time in the Inactivity time, the other
WIZ120SR User‟s Manual (WIZnet, Inc.)