WIZ120SR-EVB WIZnet, WIZ120SR-EVB Datasheet - Page 18

no-image

WIZ120SR-EVB

Manufacturer Part Number
WIZ120SR-EVB
Description
Interface Development Tools EVALUATION BOARD FOR WIZ120SR
Manufacturer
WIZnet
Type
Serial to Ethernetr
Datasheet

Specifications of WIZ120SR-EVB

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
WIZ120SR
Interface Type
Ethernet, RS-232
Operating Supply Voltage
5 V
Dimensions
110 mm x 60 mm
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Operating Supply Current
200 mA
⑤ Serial Configurations
Serial Configurations are not set by using the network interface (PC configuration tool), but
you should set from the Serial interface using Serial Commands. Click the check button
“Enable” to enter serial configurations mode. For more details, please refer to section 4
“Serial Configuration” below.
☞ This function is only supported by „UART 0‟.
⑥ Password
For security purposes, you can restrict the access of the module by imposing a password.
‟Password‟ function is only available in Server mode. If „password‟ function is enabled, the
⑦ Destination Information
When your module is set as “Client mode” or “Mixed mode” or “UDP mode”, peer IP and port
should be set in order for WIZ120SR to connect to the server (or peer).
- Use DNS : If your application needs the DNS function, click the select button and input the
domain name and the DNS Server IP address. Domain Name System (DNS) is a database system
that associates the Domain name with the actual IP address. The purpose of the DNS system is
to resolve the Domain name and represent it as an IP address. As a result, your device can
connect to an actual IP address.
- DNS Server IP: Input your DNS IP address or DNS server address provided by your Internet
Service Provider (ISP)
- Domain name : Input Domain name of connecting node. (Ex: www.wiznet.co.kr)
DNS function is good for peer IP that is not fixed (DHCP) or peer that have domain name. As a
result, you do not need to change peer IP configuration every time the peer IP change.
WIZ120SR User‟s Manual (WIZnet, Inc.)
client should input the password to access the module.
1. Execute Configuration Tool program.
2. Select „Server‟ in the “Operation Mode”.
3. Check “Enable” of “Password(TCP Server)” and enter a password of your choice
4. Click the “Setting” button
5. When the client tries to access this module, client should send the 'password' to the
server module before access is granted.
12