TC58DVM72A1FT Toshiba, TC58DVM72A1FT Datasheet - Page 25

no-image

TC58DVM72A1FT

Manufacturer Part Number
TC58DVM72A1FT
Description
IC FLASH 128MBIT 50NS 48TSOP
Manufacturer
Toshiba
Datasheet

Specifications of TC58DVM72A1FT

Format - Memory
FLASH
Memory Type
FLASH - Nand
Memory Size
128M (16M x 8)
Speed
50ns
Interface
Serial
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
0°C ~ 70°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TC58DVM72A1FT00
Manufacturer:
TOSHIBA
Quantity:
5 704
Part Number:
TC58DVM72A1FT00
Manufacturer:
TOSHIBA
Quantity:
5 704
Part Number:
TC58DVM72A1FT00
Manufacturer:
TOS
Quantity:
5 510
Part Number:
TC58DVM72A1FT00
Manufacturer:
TOS
Quantity:
5 510
Company:
Part Number:
TC58DVM72A1FT00
Quantity:
480
Part Number:
TC58DVM72A1FT00BBH
Manufacturer:
TOSHIBA
Quantity:
3
APPLICATION NOTES AND COMMENTS
(1)
(2)
(3)
(4)
(5)
CE , WE , RE
Power-on/off sequence:
sequence is necessary.
power up sequence.
starting access after about 200 s.
Status after power-on
Prohibition of unspecified commands
prohibited. Stored data may be corrupted if an unknown command is entered during the command cycle.
Restriction of command while Busy state
Acceptable commands after Serial Input command “80H”
Execution command “10H” or the Reset command “FFH”.
If a command other than “10H” or “FFH” is input, the Program operation is not performed.
The WP signal is useful for protecting against data corruption at power-on/off. The following timing
The WP signal may be negated any time after the V
CLE, ALE
In order to operate this device stably, after V
The following sequence is necessary because some input signals may not be stable at power-on.
The operation commands are listed in Table 3. Input of a command other than those specified in Table 3 is
During Busy state, do not input any command except 70H and FFH.
Once the Serial Input command “80H” has been input, do not input any command other than the Program
80
Command other than
WP
0 V
0 V
“10H” or “FFH”
V
V
CCQ
CC
XX
Power on
V
Don’t
care
IL
1.5 V
1.65 V
2.7 V
Programming cannot be executed.
10
Figure 16.
Reset
FF
Figure 15. Power-on/off Sequence
TC58DVM72A1FT00/ TC58DVM72F1FT00
TC58DAM72A1FT00/ TC58DAM72F1FT00
CC
Operation
V
becomes 2.5 V and V
IH
For this operation the “FFH” command is needed.
CC
reaches 2.5 V and CE signal is kept high in
CCQ
becomes 1.5V, it recommends
Don’t
care
2003-01-24 25/34
V
IL

Related parts for TC58DVM72A1FT