DS1821S Maxim Integrated Products, DS1821S Datasheet - Page 12

IC THERMOMETER/STAT PROG 8-SOIC

DS1821S

Manufacturer Part Number
DS1821S
Description
IC THERMOMETER/STAT PROG 8-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1821S

Function
Thermometer, Thermostat
Topology
Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
Digital
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
8 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1821S
Manufacturer:
DALLAS
Quantity:
8 680
Part Number:
DS1821S
Manufacturer:
MAXIM
Quantity:
13
Part Number:
DS1821S
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1821S+
Manufacturer:
MAXIM
Quantity:
202
Part Number:
DS1821S+T&R
Manufacturer:
Sonnenschein
Quantity:
2 000
Part Number:
DS1821S+TR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1821S/TR
Manufacturer:
DALLAS
Quantity:
15 368
INITIALIZATION TIMING Figure 7
READ/WRITE TIME SLOTS
The bus master writes data to the DS1821 during write time slots and reads data from the DS1821 during
read time slots. One bit of data is transmitted over the 1-Wire bus per time slot.
WRITE TIME SLOTS
There are two types of write time slots: “Write 1” time slots and “Write 0” time slots. The bus master
uses a Write 1 time slot to write a logic 1 to the DS1821 and a Write 0 time slot to write a logic 0 to the
DS1821. All write time slots must be a minimum of 60 μs in duration with a minimum of a 1 μs recovery
time between individual write slots. Both types of write time slots are initiated by the master pulling the
1-Wire bus low (see Figure 8).
To generate a Write 1 time slot, after pulling the 1-Wire bus low, the bus master must release the 1-Wire
bus within 15 μs. When the bus is released, the 5k pullup resistor will pull the bus high. To generate a
Write 0 time slot, after pulling the 1-Wire bus low, the bus master must continue to hold the bus low for
the duration of the time slot (at least 60 μs).
The DS1821 samples the 1-Wire bus during a window that lasts from 15 μs to 60 μs after the master
initiates the write time slot. If the bus is high during the sampling window, a 1 is written to the DS1821.
If the line is low, a 0 is written to the DS1821.
READ TIME SLOTS
The DS1821 can only transmit data to the master when the master issues read time slots. Therefore, the
master must generate read time slots immediately after issuing a read command (e.g., Read Temperature
[AAh]), so that the DS1821 can provide the requested data. All read time slots must be a minimum of 60
μs in duration with a minimum of a 1 μs recovery time between slots. A read time slot is initiated by the
master device pulling the 1-Wire bus low for a minimum of 1 μs and then releasing the bus (see Figure
8). After the master initiates the read time slot, the DS1821 will begin transmitting a 1 or 0 on the bus.
The DS1821 transmits a 1 by leaving the bus high and transmits a 0 by pulling the bus low. When
transmitting a 0, the DS1821 will release the bus by the end of the time slot, and the bus will be pulled
back to its high idle state by the pullup resister. Output data from the DS1821 is valid for 15 μs after the
falling edge that initiated the read time slot. Therefore, the master must release the bus and then sample
the bus state within 15 μs from the start of the slot.
1-WIRE BUS
GND
V
DD
MASTER T
480 μs minimum
DS1821
waits 15-60 μs
X
RESET PULSE
LINE TYPE LEGEND
Bus master pulling low
DS1821 pulling low
Resistor pull-up
12 of 18
presence pulse
DS1821 T
60-240 μs
480 μs minimum
MASTER R
X
X

Related parts for DS1821S