DS1821S Maxim Integrated Products, DS1821S Datasheet - Page 6

IC THERMOMETER/STAT PROG 8-SOIC

DS1821S

Manufacturer Part Number
DS1821S
Description
IC THERMOMETER/STAT PROG 8-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1821S

Function
Thermometer, Thermostat
Topology
Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
Digital
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
8 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1821S
Manufacturer:
DALLAS
Quantity:
8 680
Part Number:
DS1821S
Manufacturer:
MAXIM
Quantity:
13
Part Number:
DS1821S
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1821S+
Manufacturer:
MAXIM
Quantity:
202
Part Number:
DS1821S+T&R
Manufacturer:
Sonnenschein
Quantity:
2 000
Part Number:
DS1821S+TR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1821S/TR
Manufacturer:
DALLAS
Quantity:
15 368
TEMPERATURE/DATA RELATIONSHIP Table 2
HIGH-RESOLUTION TEMPERATURE READINGS
The user can calculate temperature values with higher than 8-bit resolution using the data remaining in
the counter and slope accumulator when the temperature conversion is complete. To do this the user must
first read the temperature from the 8-bit temperature register. This value is called TEMP_READ in the
high-resolution equation (see Eq. 1). The 9-bit counter value must then be obtained by issuing the Read
Counter [A0h] command. This value is the count remaining in the counter at the end of the gate period
and is called COUNT_REMAIN in Eq. 1. Next the Load Counter [41h] command must be issued, which
loads the 9-bit slope accumulator value into the counter register. The slope accumulator value (called
COUNT_PER_C in Eq. 1) can then be read from the counter by again issuing the Read Counter [A0h]
command. The slope accumulator value is called “COUNT_PER_C” because it represents the number of
counts needed for an accurate measurement at a given temperature (i.e., the counts per degree C). The
high-resolution temperature can then be calculated using Eq. 1:
Eq. 1)
High-resolution temperature readings cannot be used while in continuous conversion mode. Also, the
Read Counter [A0h] and Load Counter [41h] commands must not be used while in continuous conversion
mode.
TEMPERATURE = TEMP_READ
TEMPERATURE
+125°C*
+85°C
+25°C
-25°C
-55°C
-1°C
0°C
DIGITAL OUTPUT
0111 1101
0101 0101
0001 1001
0000 0000
1111 1111
1110 0111
1100 1001
(Binary)
6 of 18
0.5
+
(
COUNT
DIGITAL OUTPUT
_
PER
COUNT
_
(Hex)
7Dh
FFh
E7h
C9h
55h
19h
00h
C
_
COUNT
PER
_
C
_
REMAIN
)

Related parts for DS1821S