IS-DEV KIT-8 NKK Switches, IS-DEV KIT-8 Datasheet - Page 14

SMARTSWITCH DEVELOPMENT KIT 8

IS-DEV KIT-8

Manufacturer Part Number
IS-DEV KIT-8
Description
SMARTSWITCH DEVELOPMENT KIT 8
Manufacturer
NKK Switches
Series
SmartSwitch™r
Datasheet

Specifications of IS-DEV KIT-8

Main Purpose
Switches with Programmable Display
Utilized Ic / Part
SmartSwitch™OLED Rocker Switch
Primary Attributes
OLED Rocker Switch
Description/function
SMARTSWITCH Development Kit
Maximum Operating Temperature
+ 70 C
Operating Voltage
2.7 V to 5.5 V
For Use With
360-2431 - SERIAL CBL RJ11-DB9 FOR DEV KIT360-2430 - POWER SUPPLY 240VAC FOR DEV KIT360-2429 - POWER SUPPLY 120VAC FOR DEV KIT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
OLED Smartswitch Rocker
Other names
360-2421
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Attribute Block at address 0007H
The timer is 128ms. If there is no switch activity for 128ms the timer expires causing the next image, 0008H, to
be displayed. This continues until images 0009H and 000AH are also displayed. When the timer expires at
address 000AH the address is equal to the End Address. The Middle Switch Address from the Attribute Block
of 000AH is then checked.
Attribute Block at address 000AH
Since the Middle Switch Address is zero then the image at address 0007H is displayed and the Attribute Block
of address 0007H becomes active.
If the top switch is pressed in any address from 0007H to 000AH then the image at address 0001H is displayed
and the Attribute Block of address 0001H become active. Notice that the other attributes within the Attribute
Block are ignored. Notice that the loop starting at address 0007H overlaps the loop starting at address 0006H
and both end at the same End Address without interfering with each other.
Please note when the timer causes a new image to be displayed the Attribute Block of the beginning
image stays active. All other Attribute Blocks within the loop are ignored except the Middle Switch
Address of the End Address.
6. Communication Protocol
Communication initiated by Host
The controller communicates with the host via RS232 serial communication (57.6K, 1 start bit, 8 bit, 1 stop
bit). The controller receives the data via an interrupt routine that places the data on the circular receive buffer.
When the controller detects data in the circular receive buffer, the controller reads one byte and executes the
following:
When the controller executes a subroutine and expects additional information:
Current
Address
0007H
Current
Address
000AH
IS-Dev Kit 8 Users Manual A.doc
A. If the byte is a command, the controller transmits a 61H and executes the subroutine for the command
B. If the byte is not a command, it is ignored.
and upon completion of command the controller transmits 79H.
Address
0001H
Address
000CH
Switch
Switch
Top
Top
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
Address
0000H
Address
0000H
Middle
Middle
Switch
Switch
Address
0000H
Address
000AH
Bottom
Bottom
Switch
Switch
www.nkkswitches.com • Email engineering@nkkswitches.com
IS-Dev Kit-8 User Manual
Address Timer1
000AH
Address Timer1
0000H
End
End
01H
00H
80H
00H
Timer2
Timer2
Page 14 of 31
1209