IS-DEV KIT-8 NKK Switches, IS-DEV KIT-8 Datasheet - Page 19

SMARTSWITCH DEVELOPMENT KIT 8

IS-DEV KIT-8

Manufacturer Part Number
IS-DEV KIT-8
Description
SMARTSWITCH DEVELOPMENT KIT 8
Manufacturer
NKK Switches
Series
SmartSwitch™r
Datasheet

Specifications of IS-DEV KIT-8

Main Purpose
Switches with Programmable Display
Utilized Ic / Part
SmartSwitch™OLED Rocker Switch
Primary Attributes
OLED Rocker Switch
Description/function
SMARTSWITCH Development Kit
Maximum Operating Temperature
+ 70 C
Operating Voltage
2.7 V to 5.5 V
For Use With
360-2431 - SERIAL CBL RJ11-DB9 FOR DEV KIT360-2430 - POWER SUPPLY 240VAC FOR DEV KIT360-2429 - POWER SUPPLY 120VAC FOR DEV KIT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
OLED Smartswitch Rocker
Other names
360-2421
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Commands that disable switch and timer execution
Upon transmitting any of the following commands, the timer stop running and attributes for the switches
activity do not execute. The switches are still scanned and reported. The attributes execution is enabled upon
reboot/power up or by command from host.
The reason for disabling attribute execution is for faster download of images and attribute as well as command
to check the image at any address.
Command to download setup data
The command downloads the flags and other setup values. This information are stored on the MicroSD flash.
[flag] is one byte sent in ASCII HEX format. (Detail below)
[reserved] is two bytes sent in ASCII HEX format. These byte should be 00H. This is for future use. Customer
could use the last byte for storing the data version.
All other byte must be transmitted with the stated values.
Flag Byte
Example: 2A30303030 3535 3030 30303031 30303031 30303130 sets all the flags ON and set the data
version to 10.The flag takes affect when the controller is reset.
Command to upload the setup data
This command uploads the flags and other setup values to the host.
The controller transmits 10 bytes in HEX. The first two bytes are always 00H.
command format:
transmit format:
IS-Dev Kit 8 Users Manual A.doc
command format: 2BH
transmit format:
Bit
B0
B1
B2
B3
B4
B5
B6
B7
Default value=80H
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
Enable
Value
0
0
0
0
0
0
0
0
(xxH)
2AH
Buzzer
61H flag
79H flag
Switch release report flag
6EH flag
Timer expire report flag
Switch press report flag
Address change report flag Whenever a new image is displayed, the two
(xxH) (xxAH)
(xxAH)
www.nkkswitches.com • Email engineering@nkkswitches.com
[00H]
0000H
IS-Dev Kit-8 User Manual
Flag
(xxAH)
[00H]
(xxAH)
[55H]
Beeper sound for switch press
61H is transmitted in response to command.
79H is transmitted upon completion of
command.
Switch release are reported
6CH/6EH is transmitted if there is any error
during communication to host.
Timer expiration is reported
Switch presses are reported
bytes address, preceding by FCH, are
transmitted via RS232.
Controller action when flag is set
(xxAH)
[flag]
[0001H]
(xxAH)
[0001H]
(xxAH)
[reserved]
Page 19 of 31
(xxAH)
1209

Related parts for IS-DEV KIT-8