DEMOAPEXSENSOR Freescale Semiconductor, DEMOAPEXSENSOR Datasheet - Page 12

BOARD DESIGN ALTITUDE PRESSURE

DEMOAPEXSENSOR

Manufacturer Part Number
DEMOAPEXSENSOR
Description
BOARD DESIGN ALTITUDE PRESSURE
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of DEMOAPEXSENSOR

Sensor Type
Accelerometer, Pressure, Water Level, Altimeter/Barometer
Sensing Range
Multiple Ranges
Interface
I²C, SPI, Analog
Sensitivity
Multiple
Voltage - Supply
10 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
MPX2102, MPXV5004G, MPL115A2, MMA7361L
Acceleration
6 g
Sensing Axis
Triple Axis
Output Type
Digital
Interface Type
I2C, SPI
Operating Voltage
16 V
Operating Current
10 mA
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Silicon Manufacturer
Freescale
Silicon Core Number
MPXM2102A, MPXV5004G, MPL115A2, MMA7361L
Kit Application Type
Sensing - Sampling Kit / Related Components
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
MPL115A, MPXM102A, MPXV5004G
mass of water vapor and air that sits upon it. Imagine cubes of air and water vapor stacked from the ground to space. At the low
altitude there is more cubic mass above, while higher altitudes will have less of these stacked above it.
uniform with altitude, and thus the pressure is not either. The reason for altitude’s non-linear relationship is that air has infinite
compressibility. It disproportionately compresses more as weight is placed upon it. Hence the graph of Pressure vs. Altitude seen
in
Calculations for a 24-bit ADC
First: Figuring out how the 24-bit ADC translates to counts, followed by pressure and altitude.
24-bit ADC LTC2442 reference voltage is 4.1V (temperature and voltage stable shunt).
MPXM2102A has a 16.4 mV span @ 4.1V supply.
Output is gained x 98.8 by instrumentation amplifier.
Span of differential amplified signal is now 1.62V.
Low pressure end of 0 kPa input is approximately 0V seen at the differential amplifier output.
Conversely the higher end of the pressure reading at 100 kPa is = 1.62V.
SPAN of MPXM2102A after Differential Instrumentation Amplifier is now 1.62V.
of the sensor is 1.62V after the amplifier, the span of 0 to 100 kPa can be seen as a ADC value of 0 counts to 6629045 counts.
This makes each ADC count equivalent to 0.0000151 kPa or 0.0151 Pa. The LTC2442’s value was shortened to a 18-bit
conversion to minimize the baseline noise seen on the ADC output.
of the sensor is 1.62V after the amplifier, the span of 0 to 100 kPa can be seen as a ADC value of 0 counts to 103846 counts.
This makes each ADC count for the pressure span equivalent to 0.000963 kPa or 0.963 Pa.
Sensors
Freescale Semiconductor
Figure
At low elevations, a square meter on the earth’s surface has greater weight above it than at higher altitudes. This is due to the
The simplified mathematical equation used to calculate altimetry in
Assuming
ph - Pressure at height h
po - Initial Pressure point at sea level or 101.3 kPa
The 24-bit ADC would have a resolution of 4.1V/16777215 counts or 0.244 μV per an ADC count. Since the differential span
For an 18-bit ADC conversion, 4.1V/262143 equals a resolution of 15.6 μV per a single ADC count. Since the differential span
Air and water vapor will compress more at sea level and the air is significantly denser than at high altitude. The density is not
6.
p0 = 101.3 kPa
Table 4.
ADC Resolution
12-bit
16-bit
18-bit
24-bit
8-bit
h
ph
=
=
18400m log
p0 e
----------------- -
7990m
h
p0
------ -
ph
Table 3
Range of ADC Counts
is:
0 to 16,777,215
0 to 262,143
0 to 65,535
(eq. 1)
(eq. 2)
0 to 4095
0 to 255
AN3956
12

Related parts for DEMOAPEXSENSOR