DEMOAPEXSENSOR Freescale Semiconductor, DEMOAPEXSENSOR Datasheet - Page 18

BOARD DESIGN ALTITUDE PRESSURE

DEMOAPEXSENSOR

Manufacturer Part Number
DEMOAPEXSENSOR
Description
BOARD DESIGN ALTITUDE PRESSURE
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of DEMOAPEXSENSOR

Sensor Type
Accelerometer, Pressure, Water Level, Altimeter/Barometer
Sensing Range
Multiple Ranges
Interface
I²C, SPI, Analog
Sensitivity
Multiple
Voltage - Supply
10 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
MPX2102, MPXV5004G, MPL115A2, MMA7361L
Acceleration
6 g
Sensing Axis
Triple Axis
Output Type
Digital
Interface Type
I2C, SPI
Operating Voltage
16 V
Operating Current
10 mA
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Silicon Manufacturer
Freescale
Silicon Core Number
MPXM2102A, MPXV5004G, MPL115A2, MMA7361L
Kit Application Type
Sensing - Sampling Kit / Related Components
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
MPL115A, MPXM102A, MPXV5004G
the water can be high, a long enough tube combined with air column separation provides a buffer for measurement. Water and
Air are good insulators, so temperature variation can be quite drastic in a short distance. This is a design advantage in isolating
the sensor from heat.
constant, but the volume of water dispensed or left in the bottom is improved. This is done by simply making a conical bottom.
The resolution in vertical height can be used to improve the volume measurement. Additional ADC counts per a volume of water
are achieved, than a shape with a broad based bottom.
AUTO ZERO
or temperature shifts. By sampling the offset pressure (voltage output with no pressure input) and storing this value in the MCU,
the changes in the offset are negated. This improves the overall accuracy of the voltage output of the sensor, since the offset
changes are negated. Normally this would occur in a final product when there is a startup or a cycle when the sensor is not
pressurized.
CALIBRATION
at 40 cm of H
This is the best calibration, but is not implemented on the DEMOAPEXSENSOR in software rev 1.0.
Sensors
Freescale Semiconductor
Figure 9
In
A summary of the application note AN1636 is that the offset of the pressure sensor can change during board mount, stress,
The best calibration would be a two part calibration. A Pressure would be taken at 0 mm of H
Figure 10
and
2
O. The difference in ADC counts divided by 40 cm will give the number of ADC counts per a cm etc. for each sensor.
the diagram has a method to improve resolution of the water level. The vertical height measurement is kept
Figure 10
are examples of water measurement. In the hot water heater to the left, although the temperature of
Figure 11. Two Part Calibration
Second Point: Bottom of Container
First Point: 0 Level, Water Surface
2
O and also when the tubing is
AN3956
18

Related parts for DEMOAPEXSENSOR