ZX-XF12 Omron, ZX-XF12 Datasheet

no-image

ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
Smart Sensors
ZX Series
The Continuing Evolution of Smart Sensors
Presenting a New Laser-type ZX-LDA@-N Amplifier Unit

Related parts for ZX-XF12

ZX-XF12 Summary of contents

Page 1

... Smart Sensors ZX Series The Continuing Evolution of Smart Sensors Presenting a New Laser-type ZX-LDA@-N Amplifier Unit ...

Page 2

... Cylindrical Detecting small differences in Top Priority Placed on Easy Operation level Flat Advanced functions and performance plus easy operation. F This is a major feature of the ZX Series. Solder level detection in Heat-resistive soldering tanks Experience operation that doesn't get any easier. High-precision Contact Sensors Short ...

Page 3

... ZX Smart Sensors Application World Height and Level Differences Inspecting Measuring electronic PCB mold height component dimensions Identifying the number Detecting pinholes of inner caps for sake in pudding bottle caps Inspecting the height Measuring clock of the core in assembly height cardboard Measuring Measuring small ...

Page 4

... HDD chassis from aerosol cans Measuring machine Checking the flatness of tool eccentricity and brake pads vibration Inspecting the Inspecting steel eccentricity of motor plate surface areas shafts ZX-EDA ZX-TDA Counting Counting tea bags Counting copy machine staples and pins Counting containers Counting envelops 05 ...

Page 5

... Setting Amplifier functions G (actual measurement scaling, input scaling, etc.) Saving and loading Amplifier setting conditions G Note 1: Smart Monitor V3 is compatible with the ZX-L-N, ZX-L, ZX-E, and ZX-T. Note 2: Microsoft Excel is a registered trademark of the Microsoft Corporation. Note 3: System Requirements Export OS: Windows 98 or 2000 ...

Page 6

... Contents ZX-LDA-N Laser Sensors Datasheet ZX-EDA Inductive Displacement Sensors Datasheet ZX-TDA High-precision Contact Sensors Datasheet Common Precautions ...

Page 7

... Advanced Functions Made Simple. That is the Essence of Smart Style. The World's Smallest and Lightest *As of October 1, 2001 In addition to the obvious size difference, the ZX Series offers the world's lightest Sensors. Approximately the same size as a photoelectric sensor, the compact ZX Sensors contribute considerably to space-saving efforts on production sites. Naturally, response speed is also equivalent to that of a photoelectric sensor ...

Page 8

... Measurement-width % mode mode Light-receiving display/ Measurement-width transmittance display mode Equipped with a Laser Lifetime Monitor Self-detection and Display of Laser Diode Lifetime When laser diode deterioration is detected, a warning appears on the sub- digital display. Early detection enables timely, trouble-free replacement. Counting connector pins ZX-LDA-N 09 ...

Page 9

... LDA - N Advanced Functions Respond to Evolving Needs More User Friendly Zero Reset Time Display A reference value other than zero can be set as the zero reset value Linear Output Correction Various factors, such as conversion errors occurring with connected devices, may cause the output value displayed on the Amplifier to differ from the actual output from a voltmeter ...

Page 10

... The previous value comparison function effectively detects any changes between previous and present values. Displacement Time ch ch ch-1 ch Self-triggering level Self-triggering level threshold L threshold 4 3 Time ZX-LDA-N 11 ...

Page 11

... Output type NPN PNP Smart Monitor Sensor Setup Tool for Personal Computer Connection Model Appearance Model ZX-XF12 CD-ROM ZX-XF22 *1. The ZX-SFW11V3 or ZX-SW11V3 is required to use Smart Monitor with the ZX-LDA11-N/41-N. Earlier versions cannot be used. *2. The ZX-SFW11EV3 SmartMonitor can be used only to set functions and monitor waveforms ...

Page 12

... Resolution: The resolution is the deviation ( the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured with the standard reference object (white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy ...

Page 13

... The response speed of the judgement outputs is calculated as the measurement period *2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit. *3. Setting is possible via the monitor focus function. *4. A Calculating Unit (ZX-CAL2) is required. For operating details, refer to the operation manual (Cat. No. Z157). Note: ...

Page 14

... Measure- 3.5 surface ment point 7 A* 30.05 32 Receiver axis Range 39 indicators 7 3.5 7 Connector 24. dia. 46 Vinyl-insulated round cable, 5.1 dia., Standard: 500 mm * ZX-LD40L mm ZX-LD100L 100 mm ZX-LD300L 300 mm 3.8 14 4.8 25 8.6 5-R2 42.7 45 32.7 4.75 4. Emitter Receiver axis axis 47 55 Measurement center Lens (16 dia.) Lens (10 dia ...

Page 15

... Vinyl-insulated round 2.8 42 cable (gray), 2.6 dia., 22 Standard: 500 mm Connector Laser ON indicator Mounting Holes 14± Two, M3 holes Amplifier Units ZX-LDA11-N ZX-LDA41-N 30 15.5 dia. 13 Series (ZX-L-N) Receiver side Light axis center 15 15 Mounting Holes 9 0.1 Two, M3 holes Receiver side Light axis center ...

Page 16

... Cables with Connectors on Both Ends (for Extension) ZX-XC1A (1 m) ZX-XC4A ( dia. ZX-XC8A (8 m) ZX-XC9A (9 m)*1 Side-view Attachments Connectors ZX-XF12 15 Light axis center Two, 2.2 dia 2.7 Sensor communications indicator (communications operation) Sensor communications indicator (communications error) Power supply indicator ...

Page 17

... Sensor Heads or changing the Sensor Head for different detection distances. Sensor Head Cords Extendable The distance between the Amplifier Units the Sensor Heads can be extended using a ZX-XC@A Cable (sold separately). 18 Inductive Displacement Sensors Sensors with stainless steel Protective Spiral Tubes are also available. ...

Page 18

... The required parameters need to be input only into one Amplifier Unit. 0% 50% 100% 14.0 13.0 After adjustment 12.0 SUS304 11.0 10.0 AL 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1 1.0 2.0 3.0 4.0 5.0 Measurement distance (mm) Patent Pending ZX-EDA 6.0 7.0 19 ...

Page 19

... Models with Protective Spiral Tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01-S) *3. Be sure to use ZX-EDA@ Amplifier Unit version 1,200 or later with the ZX-EV04T. *4. Be sure to use ZX-EDA@ Amplifier Unit version 1,300 or later with the ZX-EM02HT. ...

Page 20

... Preamplifier Accessories *1. Resolution: The resolution is the deviation ( the linear output when connected to the ZX-EDA Amplifier Unit. The above values indicate the deviations observed 30 minutes after the power is turned ON. (The resolution is measured with OMRON's standard reference object at 1/2 of the measurement range with the ZX-EDA set for the maximum average count of 4096 ...

Page 21

... The response speed of the judgement outputs is calculated as the measurement period *2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit. *3. A Calculating Unit (ZX-CAL2) is required. Setting is possible via the monitor focus function. *4. A Calculating Unit (ZX-CAL2) is required. ...

Page 22

... Mounting Hole Cutout Dimensions Two, M3 holes 27 0.1 ZX Series (ZX-E) Smart Sensors (Inductive Displacement Type) Vinyl-insulated round cable 5.1 dia., 9 conductors, standard length: 200 mm (46) 13 (15 dia.) Connector 15.1 Vinyl-insulated round cable 5.1 dia., 9 conductors, standard length: 200 mm ...

Page 23

... Mounting Hole Cutout Dimensions Two, M3 holes 10 0 Series (ZX-E) Dimensions with Mounting Bracket Attached 22 Vinyl-insulated coaxial round cable 2.5 dia., 1 conductor, standard length M10 1 2 tightening 72 15 dia. nuts 2 toothed washers 15.6 27 58.2 Mounting Hole Cutout Dimensions ...

Page 24

... Toothed washer 15.6 27 58.2 Mounting Hole Cutout Dimensions Two, M3 holes 27 0.1 133 44 13.2 Vinyl-insulated round cable 5.1 dia., standard: 100 mm ZX Series (ZX-E) Smart Sensors (Inductive Displacement Type) 13 Connector Vinyl-insulated round cable 5.1 dia., 9 conductors, standard length: 200 mm 4.2 4.2 64 36.8 Vinyl-insulated round cable 5 ...

Page 25

... Refer to page 17 for details Series (ZX-E) ZX-XBE2 15.5 21.9 Two, M3 holes 27± 0.1 ZX-XC1A (1 m), ZX-XC4A (4 m), ZX-XC8A (8 m) Cables with Connectors on Both Ends (for Extension) Refer to page 17 for details. Smart Sensors (Inductive Displacement Type) 15 pan-head screw (with M3 spring washer) 63 ...

Page 26

... ZX Series (ZX-E) Smart Sensors (Inductive Displacement Type) 27 ...

Page 27

... Sensors Standard Sensors 4-mm measurement Highest Level of Resolution in the Industry The long-stroke ZX-TDS04@ (4-mm measurement distance) achieves precise measurements with a maximum linearity of 0.3% FS and a resolution of 0.1 µm that ranks in the top class in the industry. Complete Compatibility between Sensor Heads ...

Page 28

... Amplifier simply by connecting the Sensor Head. The distance between the Amplifier Units and Sensor Heads can be extended using a ZX-XC@A Cable (sold separately). Origin Alignment No Longer Required The differential transformer system eliminates the need for master adjustment and origin alignment every time the system is started ...

Page 29

... Sensor Heads Size Type 6 dia. Short type 6 dia. Standard type 6 dia. Low measurement type Note: The resolution refers to the minimum value that can be read when a ZX-TDA@1 Amplifier Unit is connected. Amplifier Units Appearance DC Accessories (Order Separately) Preamplifier Mounting Brackets Appearance Model ZX-XBT1 ...

Page 30

... Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1) Accessories *1. The resolution is given as the minimum value that can be read when a ZX-TDA@1 Amplifier Unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256. *2. The linearity is given as the error in an ideal straight line displacement output. ...

Page 31

... The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit. *3. Setting is possible via the monitor focus function. *4. A Calculating Unit (ZX-CAL2) is required. Note: For operating details, refer to the operation manual (Cat. No. E346) provided by OMRON. ...

Page 32

... Measurement range: 14.9 to 18.9 (TYP 84.8 84.8 133 4.2 64 36.8 11.7 2 Series (ZX-T) Smart Sensors (High-precision Contact Type) 15 dia. Connector 46 Vinyl-insulated round cable 5.2 dia., standard length: 200 mm 15 dia. 15 dia. Connector 46 20 4.2 31.5 15.8 Vinyl-insulated round cable 5.2 dia., 10 conductors, (conductor cross-section ...

Page 33

... Mounting Hole Cutout Dimensions ZXCAL2 Calculating Unit Refer to page 17 for details. ZX-SF11 ZX-series Communications Interface Unit Refer to page 17 for details. ZX-XC1A (1 m), ZX-XC4A (4 m), ZX-XC8A (8 m) Cables with Connectors on Both Ends (for Extension) Refer to page 17 for details Series (ZX-T) ZX-XBT2 (For DIN Track Mounting) (16 ...

Page 34

... Cable Extension Do not extend the cable for the Sensor and the Amplifier Unit to a length exceeding 10 m. Use a ZX-XC@A Extension Cable (sold sep- arately) to extend the Sensor’s cable. Extend the Amplifier Unit’s ca- ble using a shielded cable of the same type. ...

Page 35

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 36

Cat. No. E351-E1-02 8/06 Specifications subject to change without notice Printed in USA ...

Related keywords