ZX-XF12 Omron, ZX-XF12 Datasheet - Page 31

no-image

ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
*1. The response speed of the linear output is calculated as the measurement period
*2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
*3. Setting is possible via the monitor focus function.
*4. A Calculating Unit (ZX-CAL2) is required.
Note: For operating details, refer to the operation manual (Cat. No. E346) provided by OMRON.
Options (Actuators)
Note: For optional Actuator combinations, the circle means the Actuator is replaceable and the triangle means that a Conversion Adapter is required.
32
D5SN-TB1/TB2/TB3
Measurement period
Possible average count settings *1
Linear output *2
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
Zero reset input, timing input, reset in-
put, judgement output hold input
Function
Indicators
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Temperature characteristic
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Connection method
Weight (packed state)
Materials
Accessories
D5SN-
The response speed of the judgement outputs is calculated as the measurement period
Amplifier Units
Dimensions
Model
4.5 dia.
TB1
TB2
TB3
TN1
TF1
TA
3.5
M2.5
3.5 dia.
Item
ZX Series (ZX-T)
SR1.5
Ball type (steel)
Ball type (carbide steel)
Ball type (ruby)
Needle type (carbide steel)
Flat (carbide steel)
Conversion Adapter (stainless
steel)
6.5 0.2
5.5
Type (material)
Crisscross pattern m0.2
C0.3
1 ms
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, or 1,024
Current output: 4 to 20 mA/F.S., Max. load resistance: 300
Voltage output: 4 V ( 5 V, 1 to 5 V), Output impedance: 100
NPN open-collector outputs, 30 VDC, 30 mA max.
Residual voltage: 1.2 V max.
ON: Short-circuited with 0-V terminal or 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
- Measurement value display
- Display reverse
- Sample hold
- Self-peak hold
- Initial reset
- Hysteresis width setting
- Judgement output hold input
- (A+B) calculations *4
- Zero reset memory
- Clamp value setting
- Span adjustment
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment sub-digital display (yellow), power
ON (green), zero reset (green), enable (green)
12 to 24 VDC 10%, Ripple (p-p): 10% max.
140 mA max. (with Sensor connected), For 24-VDC power supply: 140 mA max. (with Sensor connected)
Operating and storage: 0 to 50 C (with no icing or condensation)
Operating and storage: 35% to 85% (with no icing or condensation)
0.03% F.S./ C
20 M min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions
300 m/s
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Instruction sheet
2
D5SN-TN1
, 3 times each in six directions (up, down, left, right, forward, backward)
1 dia.
Female screw
M2.5 x 0.45
Female screw
M2.5 x 0.45
Female screw
M2.5 x 0.45
Male screw
M2.5 x 0.45
Male screw
M2.5 x 0.45
Through-hole fe-
male screw
M2.5 x 0.45
Carbide steel
Screw section
Smart Sensors (High-precision Contact Type)
3
10
7
(15)
ZX-TDA11
5
Appearance
M2.5 0.45
5 dia.
(average count setting + 1).
- Present value/set value/output value display
- ECO mode
- Peak hold
- Self-bottom hold
- Direct threshold value setting
- Timing inputs
- Monitor focus
- Sensor disconnection detection
- Function lock
- Scale inversion
- Warming-up display
(average count setting + 1).
Measuring ordinary flat surfaces (standard actuator supplied with the
ZX-TDS Series)
Measurements where abrasion resistance is critical
Measured objects: Carbide (HR90) or lower.
Measurements where abrasion resistance is critical
Measured objects: Carbide (HR90) or higher.
Measuring the bottom of grooves and holes
Measuring spherical objects
Mounting D5SN-TN1/-TF1 or commercially available actuators on
ZX-TDS-series Sensors
D5SN-TF1
5.2 dia.
Carbide steel
4.3 dia.
PNP open-collector outputs, 30 VDC, 30 mA max.
Residual voltage: 2 V max.
ON: Supply voltage short-circuited or supply voltage of 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
5
(10)
3.3
5
Application
M2.5
- Number of display digit changes
- Bottom hold, peak-to-peak hold
- Zero reset
- Position teaching
- Reset input
- (A-B) calculations *4
- Non-measurement setting
- Zero reset indicator
- Pressing force alarm
0.45
D5SN-TA
2-C0.2
ZX-TDA41
12
Grooves m0.2
Applicable Sensor *
M2.55 (Through hole)
ZX-TDS@T
5 dia.

Related parts for ZX-XF12