ZX-XF12 Omron, ZX-XF12 Datasheet - Page 12

no-image

ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
Specifications
*1. Beam size: The beam size is defined by 1/e
*2. Resolution: The resolution is the deviation ( 3 ) in the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured with the standard reference object
*3. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values
*4. Temperature characteristic: The temperature characteristic is measured at the measurement point with the Sensor and reference object (OMRON’s standard reference object)
Note:
*1. This value is obtained by converting the deviation ( 3
*2. For an average count of 64. The value is 5 m for an average count of 32.
*3. For an average count of 64. The value is 5 m for an average count of 32.
Item
Optical system
Light source (wave length)
Measurement point
Measurement range
Beam shape
Beam size*1
Resolution*2
Linearity*3
Temperature characteristic*4
Ambient illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Item
Optical system
Light source
(wave length)
Measurement width
Measurement
distance
Minimum sensing
object
Resolution*1
Temperature
characteristic
Ambient illumination
Ambient temperature
Degree of protection
Connection method
Weight (packed state)
Cable length
Materials
Tightening torque
Accessories
outside the defined spot and the material around the sensing object is more reflective than the sensing object.
(white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece,
and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
vary with the object being measured.
secured with an aluminum jig.
width.
This is the value that results when a minimum sensing object blocks the light near the center of the 1-mm measurement width.
Sensor Heads (Reflective)
Sensor Heads (Through-beam)
Maximum output
Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
Model
Model
Through-beam
Visible-light semiconductor laser with a wavelength of 650 nm; JIS class1
0.2 mW max.
1-mm dia.
0 to 500 mm
8- m dia. (opaque)
4 m *2
0.2% FS/ C
Incandescent lamp: 10,000 l max. (on light-receiving side)
Operating: 0 to 50 C, Storage: 25 to 70 C (with no icing or condensation)
IEC60529, IP40
Connector relay (standard cable length: 500 mm)
Approx. 220 g
Extendable up to 10 m with special extension cable.
Case: Polyetherimide, Case cover: Polycarbonate, Unit cover: Glass
0.3 N m max.
Optical axis adjustment seal, sensor head-amplifier connection cable (1.5 m), instruction sheet
Diffuse reflective
Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max.; class 2
40 mm
Spot
50- m dia.
2 m
(entire range)
Incandescent lamp: 3,000 l max. (on light receiving side)
Operating: 0 to 50 C, Storage: 15 to 60 C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 M min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
300 m/s
IEC60529, IP50
Connector relay (standard cable length: 500 mm)
Approx. 150 g
Case: PBT (polybutylene terephthalate), Cover: Alu-
minum, Lens: Glass
Instruction sheet, Laser warning label (English)
10 mm
0.2% FS
0.03% FS/ C (Except for ZX-LD300 and ZX-LD300L, which are 0.1% FS/ C.)
ZX-LD40
2
3 times each in six directions (up/down, left/right, forward/backward)
2
(13.5%) of the strength of the beam at the beam center (measured value). Incorrect detection may occur if there is light leakage
100 mm
100- m dia.
16 m
(80 to 120 mm)
40 mm
0.2% FS
ZX-LD100
ZX-LT001
1- to 2.5-mm dia.
500 to 2,000 mm
8- to 50- m dia. (opaque) 0.05-mm dia. (opaque)
---
in the linear output that results when the sensor head is connected to the amplifier unit, into the measurement
300 mm
300- m dia.
300 m
(200 to 400 mm)
200 mm
2% FS
ZX-LD300
Regular reflec-
tive
30 mm
75- m dia.
0.25 m
(entire range)
IEC60529, IP40 IEC60529, IP50
Approx. 250 g
Case and cover:
Aluminum,
Lens: Glass
2 mm
0.2% FS
ZX-LD30V
0.35 mW max.
5 mm
0 to 500 mm
4 m *3
ZX Series (ZX-L-N)
Diffuse reflective
40 mm
Line
75 m x 2 mm
2 m
(32 to 48 mm)
Approx. 150 g
Case: PBT (polybutylene terephthalate), Cover: Alu-
minum, Lens: Glass
10 mm
0.2% FS
ZX-LT005
ZX-LD40L
100 mm
150 m x 2 mm 450 m x 2 mm 100 m x 1.8 mm
16 m
(80 to 120 mm)
40 mm
0.2% FS
ZX-LD100L
10 mm
0.1-mm dia. (opaque)
Smart Sensors
300 mm
300 m
(200 to 400 mm)
200 mm
2% FS
ZX-LD300L
ZX-LT010
Regular reflective
30 mm
0.25 m
(entire range)
IEC60529, IP40
Approx. 250 g
Case and cover:
Aluminum, Lens:
Glass
2 mm
0.2% FS
Z3X-LD30VL
13