P87C660X2BBD,157 NXP Semiconductors, P87C660X2BBD,157 Datasheet - Page 48

IC 80C51 MCU 16K OTP 44-LQFP

P87C660X2BBD,157

Manufacturer Part Number
P87C660X2BBD,157
Description
IC 80C51 MCU 16K OTP 44-LQFP
Manufacturer
NXP Semiconductors
Series
87Cr
Datasheet

Specifications of P87C660X2BBD,157

Core Processor
8051
Core Size
8-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
32
Program Memory Size
16KB (16K x 8)
Program Memory Type
OTP
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
44-LQFP
Processor Series
P87C6x
Core
80C51
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
I2C, UART
Maximum Clock Frequency
16 MHz, 33 MHz
Number Of Programmable I/os
32
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
 Details
Other names
568-3204
935273061157
P87C660X2BBD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P87C660X2BBD,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
Table 11.
2003 Oct 02
STATUS
STATUS
(S1STA)
(S1STA)
CODE
80C51 8-bit microcontroller family
RAM, low voltage (2.7 to 5.5 V), low power, high speed (30/33
MHz), two 400KB I
60H
68H
70H
78H
80H
88H
90H
98H
Own SLA+W has
been received; ACK
h
has been returned
Arbitration lost in
SLA+R/W as master;
Own SLA+W has
b
been received, ACK
returned
General call address
(00H) has been
received; ACK has
received ACK has
been returned
Arbitration lost in
SLA+R/W as master;
General call address
has been received
has been received,
ACK has been
returned
Previously addressed
with own SLV
address; DATA has
b
been received; ACK
has been returned
Previously addressed
with own SLA; DATA
b
byte has been
received; NOT ACK
has been returned
Previously addressed
with General Call;
DATA byte has been
received; ACK has
been returned
Previously addressed
with General Call;
DATA b
DATA byte has been
received; NOT ACK
has been returned
SIO1 HARDWARE
SIO1 HARDWARE
STATUS OF THE
STATUS OF THE
Slave Receiver Mode
I
b
i
2
h
C BUS AND
d ACK h
b
i
i
h
2
C interfaces
d ACK
d ACK
b
d
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
No S1DAT action or
no S1DAT action
Read data byte or
read data byte
Read data byte or
read data byte or
read data byte or
read data byte
Read data byte or
read data byte
Read data byte or
read data byte or
read data byte or
read data byte
TO/FROM S1DAT
TO/FROM S1DAT
APPLICATION SOFTWARE RESPONSE
16 KB OTP/ROM, 512B
STA
X
X
X
X
X
X
X
X
X
X
X
X
0
0
1
1
0
0
1
1
TO S1CON
STO
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
48
SI
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to not addressed SLV mode; no recognition
of own SLA or General call address
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1
Switched to not addressed SLV mode; no recognition
of own SLA or General call address. A START
condition will be transmitted when the bus becomes
free
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1. A START condition
will be transmitted when the bus becomes free.
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to not addressed SLV mode; no recognition
of own SLA or General call address
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1
Switched to not addressed SLV mode; no recognition
of own SLA or General call address. A START
condition will be transmitted when the bus becomes
free
Switched to not addressed SLV mode; Own SLA will
be recognized; General call address will be
recognized if S1ADR.0 = logic 1. A START condition
will be transmitted when the bus becomes free.
NEXT ACTION TAKEN BY SIO1 HARDWARE
P8xC660X2/661X2
Product data

Related parts for P87C660X2BBD,157