HD6473308RCP10V Renesas Electronics America, HD6473308RCP10V Datasheet - Page 187

MCU 5V 16K,PB-FREE 80-PLCC

HD6473308RCP10V

Manufacturer Part Number
HD6473308RCP10V
Description
MCU 5V 16K,PB-FREE 80-PLCC
Manufacturer
Renesas Electronics America
Series
H8® H8/330r
Datasheet

Specifications of HD6473308RCP10V

Core Size
8-Bit
Program Memory Size
16KB (16K x 8)
Oscillator Type
Internal
Core Processor
H8/300
Speed
10MHz
Number Of I /o
58
Program Memory Type
OTP
Ram Size
512 x 8
Operating Temperature
-20°C ~ 75°C
Package / Case
80-PLCC
No. Of I/o's
58
Ram Memory Size
512Byte
Cpu Speed
10MHz
No. Of Timers
3
No. Of Pwm Channels
2
Digital Ic Case
RoHS Compliant
Controller Family/series
H8/330
Peripherals
ADC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply (vcc/vdd)
-
Eeprom Size
-
Data Converters
-
Peripherals
-
Connectivity
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6473308RCP10V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6473308RCP10V
Manufacturer:
ST
0
The PWM timer counters can be read and written, but the write function is for test purposes only.
Application software should never write to a PWM timer counter, because this may have
unpredictable effects.
The PWM timer counters are initialized to H’00 at a reset and in the standby modes, and when the
OE bit is cleared to “0.”
8.2.2 Duty Register (DTR) – H’FFA1 (PWM0), H’FFA5 (PWM1)
Bit
Initial value
Read/Write
The duty registers (DTR) are 8-bit readable/writable registers that specify the duty factor of the
output pulse. Any duty factor from 0 to 100% can be selected, with a resolution of 1/250. Writing
0 (H’00) in a DTR gives a 0% duty factor; writing 125 (H’7D) gives a 50% duty factor; writing 250
(H’FA) gives a 100% duty factor.
The timer count is continually compared with the DTR contents. If the DTR value is not 0, when
the count increments from H’00 to H’01 the PWM output signal is set to “1.” When the count
increments past the DTR value, the PWM output returns to “0.” If the DTR value is 0 (duty factor
0%), the PWM output remains constant at “0.”
The DTRs are double-buffered. A new value written in a DTR while the timer counter is running
does not become valid until after the count changes from H’F9 to H’00. When the timer counter is
stopped (while the OE bit is “0”), new values become valid as soon as written. When a DTR is
read, the value read is the currently valid value.
The DTRs are initialized to H’FF at a reset and in the standby modes.
8.2.3 Timer Control Register (TCR) – H’FFA0 (PWM0), H’FFA4 (PWM1)
Bit
Initial value
Read/Write
R/W
R/W
OE
7
1
7
0
R/W
R/W
OS
6
1
6
0
R/W
5
1
5
1
173
R/W
4
1
4
1
R/W
3
1
3
1
CKS2
R/W
R/W
2
1
2
0
CKS1
R/W
R/W
1
1
1
0
CKS0
R/W
R/W
0
1
0
0

Related parts for HD6473308RCP10V