SAF-XC167CI-16F40F BB Infineon Technologies, SAF-XC167CI-16F40F BB Datasheet - Page 82

IC MCU 16BIT 128KB TQFP-144-19

SAF-XC167CI-16F40F BB

Manufacturer Part Number
SAF-XC167CI-16F40F BB
Description
IC MCU 16BIT 128KB TQFP-144-19
Manufacturer
Infineon Technologies
Series
XC16xr
Datasheet

Specifications of SAF-XC167CI-16F40F BB

Core Processor
C166SV2
Core Size
16-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, I²C, SPI, UART/USART
Peripherals
PWM, WDT
Number Of I /o
103
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 2.7 V
Data Converters
A/D 16x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LFQFP
Data Bus Width
16 bit
Data Ram Size
8 KB
Interface Type
2xASC, 2xSSC, 1xI2C
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
103
Number Of Timers
11
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 16 Channel
Packages
PG-TQFP-144
Max Clock Frequency
40.0 MHz
Sram (incl. Cache)
8.0 KByte
Can Nodes
2
A / D Input Lines (incl. Fadc)
16
Program Memory
128.0 KByte
For Use With
B158-H8963-X-X-7600IN - KIT EASY XC167CIMCBX167-NET - BOARD EVAL INFINEON CAN/ETHRNTMCBXC167-BASIC - BOARD EVAL BASIC INFINEON XC16X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
FX167CI16F40FBBNP
FX167CI16F40FBBXP
SAFXC167CI16F40FBBT
SP000094529
SP000224690
XC167CI-16F
Derivatives
Electrical Parameters
Bus Cycle Control via READY Input
The duration of an external bus cycle can be controlled by the external circuitry via the
READY input signal. The polarity of this input signal can be selected.
Synchronous READY permits the shortest possible bus cycle but requires the input
signal to be synchronous to the reference signal CLKOUT.
Asynchronous READY puts no timing constraints on the input signal but incurs one
waitstate minimum due to the additional synchronization stage. The minimum duration
of an asynchronous READY signal to be safely synchronized must be one CLKOUT
period plus the input setup time.
An active READY signal can be deactivated in response to the trailing (rising) edge of
the corresponding command (RD or WR).
If the next following bus cycle is READY-controlled, an active READY signal must be
disabled before the first valid sample point for the next bus cycle. This sample point
depends on the programmed phases of the next following cycle.
Data Sheet
80
V1.3, 2006-08