RDK-242 Power Integrations, RDK-242 Datasheet - Page 27

Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT

RDK-242

Manufacturer Part Number
RDK-242
Description
Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT
Manufacturer
Power Integrations
Type
MOSFET & Power Driverr
Datasheet

Specifications of RDK-242

Input Voltage
85 VAC to 264 VAC
Output Voltage
12 V
Maximum Operating Temperature
+ 40 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
85 VAC to 264 VAC
Product
Power Management Modules
9.2 Energy Efficiency Requirements
The external power supply requirements below all require meeting active mode efficiency
and no-load input power limits. Minimum active mode efficiency is defined as the average
efficiency of 25, 50, 75 and 100% of output current (based on the nameplate output
current rating).
For adapters that are single input voltage only then the measurement is made at the
rated single nominal input voltage (115 VAC or 230 VAC), for universal input adapters the
measurement is made at both nominal input voltages (115 VAC and 230 VAC).
To meet the standard the measured average efficiency (or efficiencies for universal input
supplies) must be greater than or equal to the efficiency specified by the standard.
The test method can be found here:
http://www.energystar.gov/ia/partners/prod_development/downloads/power_supplies/EP
SupplyEffic_TestMethod_0804.pdf
For the latest up to date information please visit the PI Green Room:
9.2.1 USA Energy Independence and Security Act 2007
This legislation mandates all single output single output adapters, including those
provided with products, manufactured on or after July 1
active mode efficiency and no load input power limits.
Active Mode Efficiency Standard Models
No-load Energy Consumption
This requirement supersedes the legislation from individual US States (for example CEC
in California).
Page 27 of 59
Nameplate Output (P
Nameplate Output (P
 1 W to  51 W
http://www.powerint.com/greenroom/regulations.htm
> 51 W
< 1 W
All
O
)
O
)
Minimum Efficiency in Active Mode of Operation
Maximum Power for No-load AC-DC EPS
0.09  ln (P
Tel: +1 408 414 9200 Fax: +1 408 414 9201
0.5  P
 0.5 W
ln = natural logarithm
0.85
O
O
) + 0.5
st
, 2008 must meet minimum
Power Integrations
www.powerint.com

Related parts for RDK-242