RDK-242 Power Integrations, RDK-242 Datasheet - Page 49

Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT

RDK-242

Manufacturer Part Number
RDK-242
Description
Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT
Manufacturer
Power Integrations
Type
MOSFET & Power Driverr
Datasheet

Specifications of RDK-242

Input Voltage
85 VAC to 264 VAC
Output Voltage
12 V
Maximum Operating Temperature
+ 40 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
85 VAC to 264 VAC
Product
Power Management Modules
01-Mar-10
RDR-242 – 30 W Open Frame Supply using TOP266VG
14 Conducted EMI
Conducted EMI were measured using a resistive load of 4.8 . Measurements were
taken with output grounded and with output floating conditions. Quasi peak and average
measurement have both ≥10 dB of margin to Class B limits.
14.1 Output Grounded
Figure 57 – Phase L1: Conducted EMI, Maximum Steady State Load, 115 VAC, 60 Hz, and EN55022 B
Limits. Output Terminal Grounded.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
Page 49 of 59
www.powerint.com

Related parts for RDK-242