RDK-242 Power Integrations, RDK-242 Datasheet - Page 6

Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT

RDK-242

Manufacturer Part Number
RDK-242
Description
Power Management Modules & Development Tools TOPSwitch-JX REF. DESIGN KIT
Manufacturer
Power Integrations
Type
MOSFET & Power Driverr
Datasheet

Specifications of RDK-242

Input Voltage
85 VAC to 264 VAC
Output Voltage
12 V
Maximum Operating Temperature
+ 40 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
85 VAC to 264 VAC
Product
Power Management Modules
2 Power Supply Specification
The table below represents the minimum acceptable performance of the design. Actual
performance is listed in the results section.
Input
Voltage
Frequency
No-load Input Power (230 VAC)
Output
Output Voltage
Output Ripple Voltage
Output Current
Total Output Power
Continuous Output Power
LPS
Efficiency
Full Load
Required average efficiency at
25, 50, 75 and 100 % of P
Environmental
Conducted EMI
Safety
Line Surge
Ambient Temperature
Differential Mode (L1-L2)
Common Mode (L1/L2-PE)
Description
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
OUT
P
Symbol
V
OUT_PEAK
V
P
T
f
RIPPLE
I
V
LINE
ES2.0
OUT
AMB
OUT
OUT
IN
11.4
Min
Designed to meet IEC950 / UL1950
85
47
80
83
0
0
Meets CISPR22B / EN55022B
50/60
Typ
12
30
Class II
Max
0.08
12.6
264
120
100
2.5
40
63
1
2
Units
VAC
mV
Hz
kV
kV
o
W
W
W
%
%
V
A
C
To meet LPS safety requirement
1.2/50 s surge, IEC 1000-4-5,
Free convection, sea level
Per ENERGY STAR V2.0
Measured at P
Differential Mode: 2 
Common Mode: 12 
Series Impedance:
20 MHz bandwidth
2 Wire – no P.E.
90 VAC / 60Hz
Comment
Page 6 of 59