Holding a reflective surface near the connector
endface may cause much greater than a 4%
reflection, which may damage the photodetector
in the OTDR.
Use proper cleaning procedures to clean all fiber
connectors before every use. Neglecting this step
or using improper procedures can cause unreliable
test results and may permanently damage the
connectors.
Use a Fluke Networks FiberInspector Video
Microscope to periodically inspect the OTDR and
loss/length option’s OUTPUT connectors for
scratches and other damage.
Read the instructions for splice machines before
using the OTDR to monitor splicing procedures.
The OTDR can interfere with the light injection
detection techniques used by some splicers.
To avoid unreliable test results, connect the ac
adapter or replace the battery as soon as the low
battery indication appears.
You may use a PC to move or copy test record
(.tst) files from a memory card, but do not rename
the .tst files. Doing so may result in loss of data.
Never remove the memory card while the
memory card’s LED is on. Doing so can corrupt the
data on the card.
Memory cards may be lost, damaged, or
accidentally formatted, resulting in data loss.
Therefore, Fluke Networks recommends saving no
more than one day’s worth of test results on a
memory card.