Description
BACKPLANE
Manufacturer
Omron
Datasheet

Specifications of C500BC061

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
xiv
Application Precautions
!
Caution
• Always ground the system to 100 Ω or less when installing the Units. Not con-
• Always turn OFF the power supply to the PC before attempting any of the fol-
Failure to abide by the following precautions could lead to faulty operation of the
PC or the system, or could damage the PC or PC Units. Always heed these pre-
cautions.
• Fail-safe measures must be taken by the customer to ensure safety in the
• Always use the power supply voltages specified in this manual. An incorrect
• Take appropriate measures to ensure that the specified power with the rated
• Install external breakers and take other safety measures against short-circuit-
• Do not apply voltages to the Input Units in excess of the rated input voltage.
• Do not apply voltages or connect loads to the Output Units in excess of the
• Disconnect the functional ground terminal when performing withstand voltage
• Be sure that all the mounting screws, terminal screws, and cable connector
• Leave the label attached to the Unit when wiring. Removing the label may re-
• Remove the label after the completion of wiring to ensure proper heat dissipa-
• Double-check all wiring and switch settings before turning ON the power sup-
• Wire correctly. Incorrect wiring may result in burning.
• Mount Units only after checking terminal blocks and connectors completely.
• Be sure that the terminal blocks, Memory Units, expansion cables, and other
• Check the user program for proper execution before actually running it on the
• Confirm that no adverse effect will occur in the system before attempting any of
necting to a ground of 100 Ω or less may result in electric shock.
lowing. Not turning OFF the power supply may result in malfunction or electric
shock.
event of incorrect, missing, or abnormal signals caused by broken signal lines,
momentary power interruptions, or other causes.
voltage may result in malfunction or burning.
voltage and frequency is supplied. Be particularly careful in places where the
power supply is unstable. An incorrect power supply may result in malfunction.
ing in external wiring. Insufficient safety measures against short-circuiting may
result in burning.
Excess voltages may result in burning.
maximum switching capacity. Excess voltage or loads may result in burning.
tests. Not disconnecting the functional ground terminal may result in burning.
screws are tightened to the torque specified in this manual. Incorrect tighten-
ing torque may result in malfunction.
sult in malfunction if foreign matter enters the Unit.
tion. Leaving the label attached may result in malfunction.
ply. Incorrect wiring may result in burning.
items with locking devices are properly locked into place. Improper locking
may result in malfunction.
Unit. Not checking the program may result in an unexpected operation.
the following. Not doing so may result in an unexpected operation.
• Mounting or dismounting I/O Units, CPU Units, Memory Units, or any other
• Assembling the Units.
• Setting DIP switches or rotary switches.
• Connecting cables or wiring the system.
• Connecting or disconnecting the connectors.
• Changing the operating mode of the PC.
Units.