PAXDR000 Red Lion Controls, PAXDR000 Datasheet - Page 10

no-image

PAXDR000

Manufacturer Part Number
PAXDR000
Description
AC, Dual Rate, Upgradeable Red
Manufacturer
Red Lion Controls
Type
Rate/Totalizerr
Datasheet

Specifications of PAXDR000

Accuracy
± (0.01% of Input Signal Frequency)
Cut Out, Panel
3.62W x 1.77H Inches
Dimensions
3.80W x 1.95H Inches
Display Digit Height
.56 Inches
Display Type
LED Adjustable
Function
Rate/Totalizer
Input Type
Switch Selectable Pulse
Keypad Type
3 Programmable Function (5 Keys Total)
Number Of Digits
Rate = 5, Totalizer = 8
Primary Type
Electronic
Range, Measurement
Rate = 0 to 99999, Totalizer = ±99999999
Special Features
Programmable Function Keys
Termination
Cage Clamp
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
PROGRAMMING MODE ENTRY (PAR KEY)
programmed in this mode. The Programming Mode is entered by pressing the
PAR
hardware lock.
permits only certain parameters to be viewed and/or modified. All meter
functions continue to operate except the front panel keys change to Programming
Mode Operations. Quick Programming Mode is configured in Module 3.
In this mode, incoming counts may not be recognized correctly, the front panel
keys change to Programming Mode Operations and certain user input functions
are disabled. Throughout this document, Programming Mode always refers to
“Full” Programming, unless “Quick Programming” is referenced.
MODULE ENTRY (ARROW & PAR KEYS)
together parameters that are related in function. The display will alternate between

the desired module. The displayed module is entered by pressing the
MODULE MENU (PAR KEY)
module discussion). The
to be changed, without changing the programming of preceding parameters.
After completing a module, the display will return to
continue by accessing additional modules.
SELECTION / VALUE ENTRY (ARROW & PAR KEYS)
the selections/value for that parameter. The arrow keys (
to move through the selections/values for that parameter. Pressing the
stores and activates the displayed selection/value. This also advances the meter
to the next parameter.
changed. Once a digit is selected, the arrow keys are used to increment or
decrement that digit to the desired number.
6.0 P
The meter normally operates in the Display Mode. No parameters can be
Two types of programming modes are available. Quick Programming Mode
Full Programming Mode permits all parameters to be viewed and modified.
The Programming Menu is organized into nine modules. These modules group
Each module has a separate module menu (which is shown at the start of each
For each parameter, the display alternates between the present parameter and
For numeric values, the
DISPLAY
PAR
and the present module. The arrow keys (
MODE
key. If it is not accessible then it is locked by either a security code, or a
Pro
NO
F1/F2
Keys
1-rAtE
Parameters
ROGRAMMING THE
Setup
Rate
PAR
PAR
RST
key is pressed to advance to a particular parameter
key may be used to select a specific digit to be
Parameters
User Input/
2-FNC
Function
Key
PAR
F1
3-LOC
Parameters
and
Program
Lock-out

Display/
F1
F2
PAR
. Programming may
) are used to select
and
PROGRAMMING MENU
F2
and B Setup
Parameters
4-tot
PAR
Totalizer A
) are used
PAR
OVERVIEW
key.
key,
PAR
M
10
5-totC
ETER
Parameters
Totalizer C
PROGRAMMING MODE EXIT (DSP KEY or at
in the Programming Mode) or the
commit any stored parameter changes to memory and return the meter to the
Display Mode. If a parameter was just changed, the
to store the change before pressing the
returning to the Display Mode, verify recent parameter changes.)
PROGRAMMING TIPS
in sequence. If lost or confused while programming, press the
over. When programming is complete, it is recommended to record the
parameter programming on the Parameter Value Chart and lock out parameter
programming with a user input or lock-out code.
FACTORY SETTINGS
starting point if encountering programming problems. All factory settings are
listed on the Parameter Value Chart following the Programming section.
ALTERNATING SELECTION DISPLAY
appear. This is used to illustrate the display alternating between the parameter
on top and the parameter’s Factory Setting on the bottom. In most cases,
selections or value ranges for the parameter will be listed on the right.
Setup
The Programming Mode is exited by pressing the
It is recommended to start with Module 1 and proceed through each module
Factory Settings may be completely restored in Module 9. This is a good
In the explanation of the modules, the following dual display with arrows will
PAR
Parameter
Indicates Program Mode Alternating Display
Parameters
* Only accessible with appropriate plug-in card.
6-SPt
Setpoint*
(Alarm)
PAR
Factory Settings are shown.

Communications
7-SrL
Parameters
 
Serial*
PAR
PAR
key (with
DSP
Selection/Value
key. (If power loss occurs before
Parameters
8-AnA

Analog*
Output
PAR
DSP
PAR

key should be pressed
displayed). This will
key (from anywhere
DSP
PAR KEY)
9-FCS
Operations
key and start
Service
Factory
PAR

Related parts for PAXDR000