PAXDR000 Red Lion Controls, PAXDR000 Datasheet - Page 14

no-image

PAXDR000

Manufacturer Part Number
PAXDR000
Description
AC, Dual Rate, Upgradeable Red
Manufacturer
Red Lion Controls
Type
Rate/Totalizerr
Datasheet

Specifications of PAXDR000

Accuracy
± (0.01% of Input Signal Frequency)
Cut Out, Panel
3.62W x 1.77H Inches
Dimensions
3.80W x 1.95H Inches
Display Digit Height
.56 Inches
Display Type
LED Adjustable
Function
Rate/Totalizer
Input Type
Switch Selectable Pulse
Keypad Type
3 Programmable Function (5 Keys Total)
Number Of Digits
Rate = 5, Totalizer = 8
Primary Type
Electronic
Range, Measurement
Rate = 0 to 99999, Totalizer = ±99999999
Special Features
Programmable Function Keys
Termination
Cage Clamp
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
function keys.
specific meter control functions. While in the Display Mode, the function is
executed when the user input transitions to the active state. (Refer to the user
input specifications for active state response times.) Certain user input functions
are disabled while the meter is in “full” Programming Mode.
programmable to perform specific meter control functions. While in the Display
Mode, the primary function is executed when the key is pressed. Holding the
F1 and F2 function keys for three seconds executes a secondary function. It is
possible to program a secondary function without a primary function. The front
panel key functions are disabled while the meter is in Programming Mode.
for the same function, the maintained (level trigger) actions will be performed
while at least one of those user inputs or function keys are activated. The
momentary (edge trigger) actions are performed every time any of those user
inputs or function keys transition to the active state.
accessed when PAR is pressed at the listed function. The function will only be
performed for the parameters entered as
configured for a function with a sublist, then that sublist will need to be scrolled
through each time to access the following user inputs or function keys
parameters.
all user inputs and function keys.
NOTE: When a user input is used to accept a quad or directional input
configured to allow complete programming access during user input lockout.
Function keys should not be programmed for
that is not locked out from the Display Mode.
6.2 MODULE 2 - U


Module 2 is the programming for rear terminal user inputs and front panel
Three rear terminal user inputs are individually programmable to perform
Three front panel function F1, F2 and RST keys are also individually
In most cases, if more than one user input and/or function key is programmed
Some of the user functions have a sublist of parameters. The sublist is
With this selection, NO function is performed. This is the factory setting for
signal, then that user input should be programmed for NO function.

When activated (momentary action), the display advances to the next display

PAR

2-FNC
USr-1

PROGRAMMING MODE LOCK-OUT
(maintained action). In Module 3, certain parameters can
be setup where they are still accessible during
Programming Mode Lockout. A security code can be
USER INPUTS
Programming Mode is locked-out, as long as activated
ADVANCE DISPLAY
USr-2
NO FUNCTION

USr-3
. If a user input or function key is

.
SER

I
PARAMETER MENU
F1
NPUT AND


P
ARAMETERS

14
F2

input is used to select the list then
active and
If a front panel key is used to select the list, then the list will toggle for each key
press (momentary action). The meter will suspend ALL operations for
approximately 1 msec. while the new values are loaded. The display will
indicate which list is active when the list is changed or when entering any
Programming Mode. In addition, the decimal point to the right of digit 1 is
displayed when List B is active.
of all the parameters. Exit programming and switch to the other list. Re-enter
programming and enter the values for

values must be reprogrammed.
data transmitted during the print request is configured in Module 7. If the user
input is still active after the transmission is complete (about 100 msec.), an
additional transmission will occur. Only one transmission will take place with
each function key depression. This selection will only function when a serial
communications Plug-in card is installed in the meter.
the Print Request function. In addition, when activated (momentary action), the
meter performs a reset of the totalizer displays configured as
aspect of this action only functions when a serial communication plug-in card
is installed. The reset action functions regardless.




When activated (momentary action), the shown display is reset.
Two lists of values are available for
To program the values for
The meter issues a block print through the serial port when activated. The
The meter issues a block print through the serial port when activated just like
FUNCTION KEYS


F
,
,



RONT


rSt
PRINT REQUEST AND RESET DISPLAYS
(
,
,





EXCHANGE PARAMETER LISTS
is selected when the user input is active (maintained action).
DISPLAY
P
. If any other parameters are changed then the other list
. The two lists are named
SC-F1
ANEL

RESET DISPLAY
PRINT REQUEST
)
Totalizer A
Totalizer B
DESCRIPTION

and


F

is selected when the user input is not
SC-F2
UNCTION
,
,


, first complete the programming
,
,
FACTORY





,
,


Pro
and
,
,






K

. The print
EY





. If a user
,
,


,
,